AUTOMATIC TECHNOLOGY AUSTRALIA PTY LTD GDO-6 v2 Slim-Drive EasyRoller® ROLL UP GARAGE DOOR OPENER OWNERS COPY Installation Instructions WARNING It is vital for the safety of persons to follow all instructions. Failure to comply with the installation instructions and the safety warnings may result in serious personal injury and/or property and remote control opener damage. Please save these instructions for future reference.
Declaration Of Conformity Automatic garage door opener model GDO-6 and accessories conforms to the applicable sections of EN60335-1 (1994), EN60335-2-95 (2001), EN55014-1 (2001), EN55014-2 (1997), EN61000-3-2 (1995), EN61000-3-3 (1994), EN 301 489-3:V1.4.1(2002-08), EN 301 489-1:V1.4.1(2002-08), EN300 220-3V1.1.1(2000-09), EN 300 2201V1.3.1(2002-09), EN50366:2003 and to the provisions of the European Directives, 73/73/EEC, 89/336/EEC and 1999/5/EC.
TABLE OF CONTENTS Safety Warnings........................................................... 4 Product Features.......................................................... 5 Operating Controls...................................................... 6 Package Contents........................................................ 8 Side Room Requirements..............................................9 Fixing Weight Bars................................................... 9 Fitting Locking Bar Covers ..................
IMPORTANT SAFETY INSTRUCTIONS Warning - It is vital for the safety of persons to follow all instructions. Failure to comply with the following Safety Rules may result in serious personal injury and/or property damage. For ADDITIONAL SAFETY protection we STRONGLY recommend the fitting of a Photo Electric Beam. In most countries Photo Electric Beams are mandatory on all garage doors fitted with automatic openers.
FEATURES Thank you for purchasing the SlimDrive EasyRoller® Automatic Garage Door Opener. This opener is designed to suit vertical operating continuous curtain roll up doors. The components and materials used in this opener are of the latest technology and highest quality. Listed below are some of the many features. OPERATION To open or close the door simply press the keyring transmitter, easy access transmitter, or optional wall switch for two seconds.
OPERATING CONTROLS 1. P. E. SHUNT. The shunt has to be removed when connecting a Photo Electric Beam. NOTE: P.E. SHUNT must not be removed otherwise the opener will not function correctly. Remove only when a P.E beam is to be connected. 6. NOTE: The close safety obstruction detection is inoperable whenever the Close Drive button is used to move door. This button is disabled after initialisation. 24V OUTPUT supplies 24V DC at 30mA to power an external receiver, or electronic device, etc.
OPERATING CONTROLS 10 11 12 13 14 15 16 17 2 3 4 5 6 7 8 9 1 1) 2) 3) 4) 5) 6) 7) 8) P.E. SHUNT, PE INPUT, OSC INPUT, LIGHT INPUT, 24V DC OUTPUT LIGHT CODE BUTTON (BLACK) CODING LED (RED) DOOR CODE BUTTON (BLUE) DOOR STATUS LED (YELLOW) CLOSE DRIVE BUTTON (RED) CLOSE LIMIT LED (RED) AUTO CLOSE TIME BUTTON 9) 10) 11) 12) 13) 14) 15) 16) 17) 7 ENGAGE/DISENGAGEMENT HANDLE INC.
PACKAGE CONTENTS ITEM QUANTITY GDO-6 SLIM-DRIVE EASYROLLER® DRIVE UNIT 1 EASY ACCESS TRANSMITTER EAT-1 (NOT INCLUDED IN SOME MODELS) 1 KEY RING TRANSMITTER PTX-4 2 PTX-4 WALL MOUNT BRACKET 1 ALKALINE BATTERY A23 12V 2 WEIGHT BAR (NOT INCLUDED IN SOME MODELS) 1 PAN HEAD SCREW M4x50mm (NOT INCLUDED IN SOME MODELS) 2 NILOCK HEX NUT M4 (NOT INCLUDED IN SOME MODELS) 2 FLAT WASHER I.
BEFORE INSTALLATION IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION FIG. 1 40 Warning: Incorrect installation can lead to severe injury. Follow ALL installation instructions. 95 SIDE ROOM REQUIREMENTS Fig. 1 shows the minimum and recommended side room that is required to mount the opener. The distance between the edge of the door curtain and the inside of the bracket must be at least 40mm. However, for easier access it is recommended that at least 95mm is allowed . 1.
EASY ACCESS TRANSMITTER 4. EASY ACCESS TRANSMITTER FIG. 4 The Easy Access Transmitter is prepared ready for use with the battery pre-installed. Before the transmitter can be operational, the transmitter code has to be stored into the openers memory. To store the code refer to Step 10.1 on page 15. REMOVING THE COVER TO REPLACE BATTERY 1. Rotate the cover Clockwise to CLOSE 2. Rotate the cover Anti-clockwise to OPEN REMOVING THE BATTERY (Battery Type: 3V Lithium Battery CR1220).
MOUNTING THE OPENER 5. FIXING DRIVE UNIT TO THE DOOR FIG. 8 The EasyRoller Drive Assembly can be fixed to the roll up garage door in a variety of ways. Described below is one method of fixing. Make sure there is enough side room to slide the drive assembly onto shaft. PLEASE NOTE: THE INSTRUCTIONS FOR FIXING THE DRIVE ASSEMBLY TO THE DOOR ARE FOR RIGHT HAND INSTALLATION. FITTING DRIVE UNIT TO DOOR (Fig. 8, Fig. 9, and Fig. 10). 1.
SETTING LIMITS 6. FIXING DOOR CURTAIN TO DRUM WHEEL FIG. 11 The door curtain has to be secured to the drum wheel with suitable fasteners. 1. With the door in the fully closed position, mark the curtain (Fig. 11) on both ends of the door. 2. Open door slightly to have access to the marked positions. Secure the curtain to drum wheel using self drilling screws (two on each end). The screws should be at least 90° apart. 7.
SETTING LIMITS 8. SETTING DOOR TRAVEL LIMIT POSITIONS VIA THE REMOTE CONTROL FIG. 14 IMPORTANT NOTE: The O/S/C button will not function until the open and close limits position are set. NOTE: The opener is factory preset for installation on the RIGHT HAND SIDE. When the opener is mounted on the left side of the door the opener will travel in reverse. To change the direction of travel for LEFT HAND SIDE installation do the following: NOTE: Remove the control panel cover for access.
SETTING SAFETY OBSTRUCTION FORCE 9. SAFETY OBSTRUCTION TEST FIG. 16 Please take care when testing the Safety Obstruction Force. Due to Excessive forces failure to follow this warning may cause SERIOUS PERSONAL INJURY and/or property damage. The test below should be repeated at regular intervals (approximately every two months). 9.1 TESTING CLOSE CYCLE 1. Open the door by pressing the Yellow O/S/C button (Fig. 16). 2.
CODING TRANSMITTERS 10. SETTING TRANSMITTERS CODES FIG. 18 The memory in the opener can store up to 24 remote control transmitters. Make sure to insert the battery into the transmitter with the correct polarity. NOTE: Remove the control panel cover for access. Remember to replace the cover when set up is complete. 10.1 STORING THE TRANSMITTERS CODE 1. Press and hold Door Code button (Fig. 18). 2.
CODING TRANSMITTERS 11. STORING TRANSMITTER(S) FROM A REMOTE LOCATION FIG. 20 Using this method you don’t need to have access to the control panel on the Door Opener. However, you do need a transmitter that is pre coded to the controller’s receiver. IMPORTANT NOTE: The Door or Courtesy Light must be activated when the step below is performed. The moving Door or Light switching on is to confirm from a remote location that, the correct button was pressed, and the transmitter is in range of the Opener. 1.
PE BEAM AND AUTO CLOSE 13. FITTING THE SAFETY PHOTO ELECTRIC BEAM SENSOR (OPTIONAL) FIG. 22 Locate the Photo Electric Beam (P.E.) (normally closed contact type) in a strategic location within doorway. We recommend 150mm above the floor level and as close as possible to the door opening, inside the garage. Remove shunt from P.E connector (Fig. 22) and connect the wires from the P.E. wiring harness as per Fig. 23.
FINAL SET UP NOTE: Remove the control panel cover for access. Remember to replace the cover when set up is complete. FIG. 25 16. SETTING COURTESY LIGHT TIME The preset courtesy light time on the door opener is 3 minutes. This time can be changed by the following: 1. Press and hold both the Auto Close Time button and Force Margin Set buttons (Fig. 25). 2. While holding the two buttons, press Open button. Each press will add 10 seconds to the light time. 3.
PARAMETERS DOOR STATUS INDICATORS OPEN LED GREEN DOOR OPENER STATE OPEN CLOSE LED RED DOOR STATUS LED YELLOW BEEPER ON ON CLOSE FLASHING OPENING FLASHING CLOSING DOOR TRAVEL STOPPED FLASHING DOOR OBSTRUCTED WHEN OPENING FLASHING FLASHING DOOR OBSTRUCTED WHEN CLOSING BEEPS WHILE DOOR IS MOVING FLASHING OPENER OVERLOADED ALTERNATING FLASHES DOOR IN OPEN POSITION WITH AUTO CLOSE MODE SELECTED ONE SECOND FLASHES MAINS POWER INTERRUPTED PET MODE ENGAGED ALTERNATING FLASHES RAPID FLASHES ON
DEFAULT SETTINGS AND SPECIFICATIONS FACTORY DEFAULT SETTINGS DEFAULT STEP MAXIMUM MAXIMUM MOTOR RUN TIME 25 Secs. — — COURTESY LIGHT TIME 3 Mins. 10 Secs. 4 Mins. 8 1 20 0 Secs. 1 Sec. 4 Mins. OBSTRUCTION FORCE MARGIN AUTO CLOSE TIME TECHNICAL SPECIFICATIONS INPUT VOLTAGE: 230V - 240V AC 50Hz CONTROLLER VOLTAGE: 24V DC STANDBY POWER: 1.
TROUBLE SHOOTING SYMPTOM POSSIBLE CAUSE REMEDY Door will not operate. Mains power not switched on. Door is obstructed. Door is locked or motor jammed. Door tracks/hardware damaged. Switch on mains power. Remove obstruction. Unlock door or remove jam. Door requires service/repair by qualified technician. Door starts to close but automatically reverses to open position. Adverse weather conditions (wind or cold) causing door to stiffen and become tight in the tracks. Possible obstruction in the doorway.
SPARE PARTS LIST WHEN ORDERING SPARE PARTS PLEASE QUOTE THE ORDER CODE NUMBER TO YOUR INSTALLER/DEALER.
WARRANTY AND EXCLUSION OF LIABILITY 1. This warranty is an addition to any non-excludable conditions or warranties that are implied into this contract by relevant statute, including the Trade Practices Act 1974 (Cth). (Trade Practices Act applicable to Australia only). 2.
Purchased From ___________________________________ Phone ______________________ Installed By _______________________________________ Date _______________________ Serial No. ________________________________________ AUTOMATIC TECHNOLOGY AUSTRALIA PTY LTD ABN 11 007 125 368 17-19 Advantage Rd, Highett, Victoria, Australia 3190 Tel: +61 3 9532 2788 Fax: +61 3 9532 2799 Web: www.ata-aust.com.au Email: sales@ata-aust.com.au ATA GARAGE DOOR OPENERS LTD Registered No.