Instruction Manual

28
ATS-3AM & ATS-2AM Dominator Tempo & Syncro Instruction Manual
7.4. Service / Warning Indicator
Flashes Issue Remedy
x 1
Normal operation (door is fully open)
x 2
PE is preventing door from moving
Clear away any obstructions. Test Door. If unable to move the door and
suspect beam is faulty, enter Safety Beam Emergency Close by pressing
and holding a pre-coded button on the remote control for more than five
seconds and the door will start closing.
x 3
NOT AVAILABLE
x 4
Wireless PE battery is low Change PE Battery
x 5
NOT AVAILABLE
x 6
Maintenance is due after pre-set number of cycles. Contact dealer to arrange service.
x 7
Backup battery is faulty Contact (800) 934 9892 within America for assistance
x 8
Door has hit an obstruction
Clear away any obstructions and test door opens/closes correctly. (If door
is damaged, contact your door professional)
x 9
Motor has overloaded or stalled
Check the doors operation by disengaging the motor and ensuring the
door runs smoothly. If necessary make door adjustments or contact your
door professional.
x 10
Battery backup activated - mains power is off
Main light will flash (3) three times at the start of the cycle to indicate
opener is running from battery backup and 10 flashes at the end of cycle.
Check power supply.
Flashes FAULT
x 2
or x 3
Failed while profiling door after setting limits. Can be caused by any event
which cause door to stop. For example P.E beam being blocked on closing,
hit an obstruction, etc. Also can occur if battery is activated.
x 4
or x 5
Position Fault
x 6 Motor driving in wrong direction
x 7 Memory fault
x 8 Motor current sensor fault.
7.4.3 Connecting or Disconnecting Accessories:
When disconnecting or reconnecting accessory base station modules (Wireless PE Beams or Autolock) press the MODE button repetitively until the GEAR
LED is on, the press the STOP / SET button until the main courtesy light stops flashing.
7.4.2 Main Light = FAULT Status Indicator (when MODE is on):
When MODE is ON, light flashes indicated number of times. When first triggered, the beeper will sound the indicated number of beeps. Attempting to
operate the door will result in the beeps being heard again. The below table identifys the issues and remedies.
7.4.1 Main Light = Service / Warning Indicator:
Requirements for a service and user warnings are indicated after operation by the main light repeatably flashing OFF a number of times followed by a
pause. When the alert is first triggered the beeper will also sound. The below table identifys the issues and remedies.