Parameters
Door Status Indicators
Door Opener State Open LED 
Green
Close LED 
Red
Door Status 
LED yellow
Beeper
Open On
Close On
Opening Flashing
Closing Flashing
Door travel stopped Flashing
Door obstructed when 
opening
Flashing
Door obstructed when closed Flashing Beeps 
while door 
is moving
Opener overloaded Alternating fl ashes Alternating fl ashes
Mains power interupted Rapid fl ashes
Buttons Function
Operate Opens/Stops/Closes the door
Door code Codes a transmitter button for OPERATE function
Force Margin Set + plus (+) Increases the obstruction force margin setting
Force Margin Set + Minus (-) Decreases the obstruction force margin setting
Force Margin Set (then) Set Reloads the factory set default obstruction force 
margin setting
Close for 6 seconds Clears the door limits set positions. Limits then need 
to be reset
Set (then power on) & hold until all LEDs are off Deletes control parameters excluding transmitter 
storage memory
Door Code (then power on) & hold until all LEDs 
are off
Deletes all transmitter stored in memory.
Set for 2 seconds Re-initialises the Opener to re-calculate force margins