Instruction manual
Coal-trol Digital™ – Model TS2 THERMOSTAT
Automation Correct LLC
6/2006 R0
www.automationcorrect.com
Page 2
Instruction Manual
Coal-trol Digital Feature Overview
The Coal-trol  Digital System  is a complete control system  designed for  automatically fed stoker 
stoves  and  furnaces  utilizing  anthracite  fuel.  The  stove-mounted  Control  Module  and  the  wall- 
mounted Coal-trol Thermostat work together to supervise all stove operations and maintain room 
temperature to within ±1°F of the desired setting. 
The Control Module controls the coal feed rate, combustion blower fan, convection blower fan, fire 
igniter (additional hardware required when available).
All  connections  to  stove  blowers,  motors,  and  safety  interlocks  are  done  through  standard 
120VAC cord receptacles.
The Control Module has a lighted power On/Off switch and 120VAC cords for all controlled loads.
The  Coal-trol  Thermostat  may  be  located  up  to  100  ft.  from  the  Control  Module.  Proper 
temperature control only requires that the heat generated by the  stove is readily  communicated  
to  the  thermostat.  (A  forced  air  furnace  located  in  the  basement  with  the  thermostat  mounted 
upstairs can work fine).
Fuel  feed  is  continuously  adjusted   to  maintain  room  temperature  as  set  on  the  Coal-trol 
thermostat. The  Convection  blower  is  automatically  started  and  continuously  adjusted  to  match 
the heat output of the stove.
Two temperature setbacks automatically change the temperature at prescribed times set by the 
user on a 24 hour time cycle.
A room high temperature limit shuts off the stove if feeder failure occurs.
The initial setup of minimum and maximum feed rates, and selection of either dual-motor or single 
motor  (Tri-Burner) stoker  styles,  allow  Coal-trol  Digital  application  to  a  wide  variety  of  stove 
configurations and brands.
A One-touch Feed mode assists in starting a fire by continuously stoking coal for 10 minutes at a 
100% rate.
All settings, except for time of day clock, are maintained during power loss without batteries.
Power  loss  ride-through   allows  the  thermostat  to  continue  stove  operation  if  power  is  restored 
within 2 hours. 
Test Mode sequences all motors and blowers to assist in installation and troubleshooting.
The Coal-trol  Digital TS2  Thermostat  features  an LCD  display, one  LED indicator, and  3 
pushbuttons for indication and control of all settings.