Locating the Thermostat
The room temperature sensor is located in the Thermostat. For proper operation, the sensor must 
be exposed to the heat produced by the stove. The preferred mounting locations include: on an 
inside wall, away from the direct air stream of the convection blower, and away from radiant heat 
produced by the stove. Note that the Thermostat does not have to be within the same room as the 
stove. For example, a coal  furnace ducted  to the  return air  plenum of  an oil  or gas furnace will 
give good results if the Thermostat is mounted next to the oil/gas furnace thermostat.
25 ft. Thermostat Cord
Connect Thermostat to Control Module
The provided  25ft. cord  may be  extended with  an 8 
pin, RJ45 to RJ45 coupler and/or standard computer 
network  cable.  The  cable  must  be  a  'through'  type, 
not a crossover type. Note: The Coal-trol thermostat 
and Power Module cannot be connected to computer 
networks through this cable.
Connect  the  Thermostat  cable  to  the  THERMOSTAT  connector  on  the  Control  Module  and  the 
Connector on the rear of the TS2 Thermostat.
HiTemp    
Room Over-Temperature Cutout
The  STATUS  indicator  light 
blinks every second.
The  temperature  sensor  in  the 
thermostat  has  detected  a 
room temperature above 98°F/
37°C  and  has  disabled  the 
Stoker  motor,  combustion  air 
motor  and  the  Convection 
Blower.  If  installed,  the  Power 
Vent motor continues to run.
DISPLAY ACTION NOTE
STOP
CAUTION:  Before  proceeding, 
investigate  the  cause  of  the 
over-temperature condition.
The  HI  TEMP  display  may 
indicate  a  problem  with  your 
stove,  chimney,  or  Coal-trol 
Digital System. 
Press MENU button to Reset.
The  thermostat  will  not  allow 
the  MENU  button  to  reset  the 
thermostat  until  the  room 
temperature  is  less  than  97°F/
35°C