Note: The strobe signal connection is shared with Output 3. If a non-zero value is defined for the Strobe Pulse Length 
value (in VPM – Impact – General), the strobe is active. If the value is zero, Output 3 is active. 
CAUTION 
Power is available directly to the Output Device, independently from the 
Power Supply Switch inside the CBX. 
Figure 14 - Open Emitter Output Using CBX Power  Figure 15 - Open Collector Output Using CBX Power 
OUTPUT CONNECTIONS USING EXTERNAL POWER 
Figure 16 - Output Open Emitter Using External Power 
Figure 17 - Output Open Collector Using External Power 
EXTERNAL ILLUMINATORS 
If an External Illuminator (strobe light) is used, it can be powered from the CBX connection box. 
It must be connected to the Vdc and GND terminal clamps. The strobe signal connection is 
shared with Output 3. If a non-zero value is defined for the Strobe Pulse Length value (in VPM – 
Impact – General), the strobe is active. If the value is zero, Output 3 is active. 