User guide
User Guide P. 9
Diagnostics – Parking Light Flash Table
Flashes Description
1
• Doors locked, starter kill armed.
• Run time has expired.
•
Ι & ΙΙ button pressed.
• Start signal received by the module.
• Cold weather mode cancelled.
2 slow flashes followe
d
by 8 quick flashes
• Reset from manual to automatic
2
• Doors unlocked, starter kill disarmed.
• Remote start attempt cancelled by
remote.
• Doors unlocked, starter kill disarmed.
• Exiting ignition valet
• Power-up reset
• Board set from manual to automatic; power
ON.
• Power ON to OFF (automatic transmission).
3
• Entering cold weather mode.
• Entering and exiting ready mode.
Entering ignition valet
3 slow flashes… …after a failed start attempt The module did not detect a tach signal.
4
• +12 V detected on the brake input wire either while cranking or during run time.
• Entering multi-speed tach programming.
• Board set from automatic to manual; power ON.
Power ON to OFF (manual transmission).
5 Slow • Start attempt failed because no tach signal has been programmed.
5 Fast • Tach signal programmed.
6 • A remote start was attempted while a tach-before-crank signal was detected before cranking.
8 • Unit reset see “Resetting the Module” (p.Error! Bookmark not defined.)
10 • A ground (-) signal was detected on the hood pin input wire.
When pressing ΙΙ
15 quick flashes…
• The parking brake is connected to ground (automatic transmission).
1 pause
1pause
5 flashes
• Transmitter has been programmed.
• [During the transmitter programming procedure]
1 – pause – 2
• There was a remote start attempt while the vehicle was in valet mode.
Failed start: vehicle’s low battery voltage.
ON SOLID for 3
seconds….
…followed by 1 flash
…followed by 3 flashes
Exiting cold weather mode
Entering cold weather mode
ON continuously
• Idle mode: Idle mode is engaged
Run time: The vehicle has been remote started and is in run time
ON continuously
While the brake
pedal is pressed.
• Confirms that cold weather mode is engaged
ON 2 seconds • The hood has been opened and a ground (-) signal has been detected on the hood pin input wire.
ON 4 seconds • Locking or unlocking a door (with Door pulses configured to 4 sec.)
ON 20 seconds • The hood pin has been flashed and you are now in the programming centre.
Constantly flashin
g
up to 25 sec.
• Panic mode is triggered.