Specifications
RSLinx – Training Guide C - 9
Analog Emulation
Since the data table is fully emulated, you can simulate values raising and lowering if
necessary by means of ladder logic, either in debug rungs (explained later), or simply rungs
in the normal logic which would, via timers and math/compare/move instructions, raise
and lower integer values in the data table. You could also use an HMI such as RSView32
or WINtelligent VIEW to change values, e.g., via slider bars or other downloading
functions.
Although emulation of BTR/BTW (block transfer instruction) reads and writes is not
supported (as there are no real world analog signals to read or write), there is limited
emulation (DN and EN bits are set). PID and MSG instructions are not supported. For
additional information, see the RSLogix Emulate 5 or 500 manual or the Help system