Installation manual
SIMDOS diaphragm metering pump Technical data
KNF Flodos BA_SIMDOS_EN_02_160044.docx
Translation of original operating manual 9
4.5. Electrical data
Parameter Value
Nominal mains voltage [V] 100–240 V AC +/- 10%
Frequency [Hz] 50–60 Hz
Maximum current consumption
AC 100 V / 115 V / 240 V [A]
0.1 / 0.09 / 0.05
Max. watt consumption [W] 10
Pump DC voltage [V] 24 V DC
Max. current consumption, DC
RMS 24 V [A]
0.4
Max. short-term peak current [A] 1.7
Power supply protection Electronic overload protection
Pump protection Electronic overload protection
Pump protection type IP 65
Power supply protection type IP 40
Tab. 8: Electrical data
4.6. Other parameters
Parameter Value
Permitted ambient temperature +5 to +40°C
Permitted medium temperature +5 to +80°C
Rated speed 200 rpm
Service life > 10,000 h (100 million strokes)
Noise level < 40dBA
Pump weight
1)
0.9 kg
Tab. 9: Other parameters
1) Pump weight may differ slightly for some pump versions.