Installation guide

P. 6 Installation Guide CT-3400 TW
5
YELLOW
+12 V
Parking
Light
output
This wire provides a +12 V output (15 A max.) and must be connected to
the Parking Light wire that tests +12 V when the Parking lights are
ON.
Note: Ensure that the voltage does not vary when the dimmer control
switch is turned up or down. If this is the case, it is not the right wire.
There is a also a negative Parking Light output. Only one of these
two different outputs needs to be connected.
12-Pin Accessories Harness
This harness has the remaining wires used in some remote starter installations as well as the
optional user convenience outputs.
Wire Description
1
BLUE
(–) Zone 3
or AUX 3 output
500 mA negative output. This can be used to control trunk release (1-sec.
pulse) or to operate as a constant output as long as the
TRUNK button is held
pressed (for Sunroof or Window close).
2
BROWN
(–) Lock
Programmable 500 mA 1/10-sec., 7/10-sec. or 4-sec. negative output.
3
GREEN
(–) Unlock
Programmable 500mA 1/10-sec., 7/10-sec., 4-sec. or 1/4-sec. double-pulse
negative output.
4
WHITE / BROWN
(–) Arm
Max 500 mA ground signal when the doors are locked by remote control.
This wire will go to ground 1/4 sec. before the
LOCK pulse, and go OFF 1/8 sec
after it. Note: The system will also give a rearm pulse on this wire after
remote-start shutdown.
5
WHITE / GREEN
(–) Disarm
Max 500 mA 1-sec. ground pulse when the Doors are unlocked by remote
control. Connect to the OEM Disarm wire of the vehicle. Note: The system
will also give a disarm pulse on this wire before remote starts.
6
BLUE / WHITE
(–) AUX 1 output
This output will provide a 1-sec. negative output (500 mA) when the
UNLOCK
button is pressed a second time on the transmitter (priority door access) or
otherwise when the
LOCK button is pressed (horn confirmation).
7
WHITE / ORANGE
(–) Starter Kill
(armed output)
The unit is equipped with a selectable passive- or active-arming Starter Kill
circuit that will immobilize the vehicle when the system is armed. This wire will
provide a constant 500-mA negative output when the system is armed (locked
by remote) or if remote started. This wire should be connected to a Single Pole
Double-Throw Relay (This wire will connect to Pin 85, on the Relay, and Pin 86
will be connected to the Ignition wire).
A second benefit of the Starter Kill is the Anti-Grind feature. When the vehicle
has been remote started the Anti-Grind prevents the starter motor from re-
engaging when the ignition key is inserted in the Ignition switch and
accidentally turned to the
CRANK position (The Starter Kill output becomes
active during remote starts).
8
ORANGE
(–) AUX 2 output
Negative 500mA output. Can be programmed for one of the following four
options:
(1) Constant while the
LOCK and UNLOCK buttons are pressed + 1 sec. after
release of buttons.
(2)
LOCK + UNLOCK toggles ON/OFF. (Max. 30 sec.)
(3)
LOCK + UNLOCK toggles ON/OFF. (Max. 60 sec.)
(4) Priority door access.
9
PURPLE
(–) External
Trigger input
This input will start the vehicle when it receives a 1-second ground pulse
from an external pager system or timer module. It will also shut the vehicle
down upon a 1-sec. pulse when running under remote control.
Option 1 – (-) input Trunk pin: When the external trigger wire is programmed as