User`s manual

AVY16-ES100 User’s Manual AuviTran 19
Below is an example using AVY16-ES100 in an EtherSound redundant ring, and an
AuviTran AVM500-ES matrix, used as a bridge between the ring and others classic daisy-
chain networks.
- AVY16-ES100 #1 is set as Preferred Primary Master (clock source when ring closed)
- Third port of AVY16-ES100 #2 is used to monitor the ring
- 32 channels can be handled by the Yamaha console
- 32 channels remains, that can be handled by AVM500-ES
- If a purple link is broken, audio transmission is recovery few ms after broken link