Specifications

37
2) TELEPHONES, SIGNAL TEST TIME
Tel. 1
Tel. 2
Tel. 3
Tel. 4
Test Signal Time
Auto Arm Time
010
011
012
013
Address
014
016
Time
(00:01)
00:00
Tel. 1 is ‘Follow Me’. Tel. 2 and 3 are communicator option. Tel. 4 is Dialer. Test signal to central station. Codes define at
(According to programming). Maximum 16 digits + 4 pauses each Tel. Number. address. 237 & 255. Enter time in 24 hour format
NB: Press and hold the ‘9’ key until the keypad beeps, after the address to erase telephone numbers.
To insert * in the phone number: Enter to program mode, program system to dial in DTMF, Hold-down keys # and * (as panic), ‘A’ will be displayed.
To enter Pause during dialing hold-down key ‘0’.
3) OUTPUTS and TIME-OUTS
Entry
Delay 1
Entry
Delay 2
Exit
Delay
Siren
Time
ON Siren
Time
OFF Siren
Time
A1
Time
A2
Time
Chime
Time
Abort
Delay
Sec's
Sec's x 4
Sec's x 4
Minutes
Sec's
Sec's
Sec's
Minutes
Beeps
Sec's
060
061
062
063
064
065
066
067
068
069
1
2
0
0
0
8
0
4
1
5
0
4
3
0
0
4
0
3
0
0
4) SYSTEM FEATURES
Feature
070
Feature
071
Enable-Siren/Bell Test upon Arming
1
Enable-Erase F. Me number on Disarm
1
Enable-3 Beeps upon Disarming
(2)
Enable-Instant Arming via Key 5
2
Enable-Buzzer upon Entry Delay
(3)
Enable-SLO 1 as reset for smoke detector
3
*
Enable-Keypad Tactile Beep
(4)
Enable-Display Troubled/Open Zone
4
Disable-4 LEDs display during Armed
5
Enable-Manual Bypass via Code No. 1
5
Enable-Battery Test upon Arming
(6)
Lock in Armed after Tamper Alarm
6
Enable-Code No. 7 for Access Control
1
7
*
Enable-Momentary Key-Switch
(7)
Enable-Keypad Panic
(8)
Enable-Code ‘8’ as one time code
8
Feature
072
Feature
073
Enable-Bell mode
(1)
Enable-Display troubled zones at Disarmed
1
Enable-Detailed alarm history
(2)
Enable-Test to central station each hour
2
Enable-Report Opening/Closing
(3)
Enable-Self contain Bell (0V at alarm) **
3
Activate ON output for ADSL filter line-cut
4
Enable-Buzzer upon exit delay
4
Enable-Report bypassed zones at Arming
5
Enable- Group Bypass when Armed by Key
5
***
Enable-Exit delay when delayed zones clear
6
Enable- 2 Siren Beeps at Disarming by Key
6
Enable -’ON’ output as SVM trigger
7
Enable-A1 Output active during siren time
(7)
Enable -Codes reset to default by hold *& #
(8)
Enable – Inverting of Outputs polarity
8
Keypad Panic Alarm
074
Tamper Alarm
075
Enable-Siren on Panic
1
Enable-Tamper zone 24H zone
1
Enable-Alarm 1 On Panic
2
Enable-Alarm 1 on Tamper
2
Enable-Alarm 2 On Panic
3
Enable-Alarm 2 on Tamper (not at 2055,88)
3
Enable-SLO On Panic
(4)
Enable-SLO on Tamper
4
Enable-Telephone Report
(5)
Enable-Last zone as KEY (from V 3.05)
5
Enable-Buzzer alarm on Panic
6
Enable-Tel. Line test at Disarm Mode
6
Enable-Enable Emergency Buttons
7
Enable-Activate SLO at Tel. Line fail
7
Enable- Double Zone (AV-2055,2088 only)
8
Enable-Dialer reports on AC fail
8
Feature
076
Enable -’SLO1’ output for SVM trigger
1
Enable – Remote A1 activation by DTMF
2
Enable - Auto Reset before alarm time out
3
Enable – Alarm panel DTMF control
(4)
Enable – Sounder for Tel. line fault
5
Enable – Siren for tel. line fault
6
Enable - Bypass Answering Machine
7
Enable-Echo Cancellation Tone (AUSTEL)
8
1
- Code No. 7 for access control drives SLO 1 output ** Self-contained Bell is operative if Bell mode selected
*** Available in AV-2055, 2088, 2016 (not in ‘P’ version). In Australia, program ‘8’ in address 076.
* Those features cannot be enabled at the same time.
Address 077, CS test day: 1 - Sun 2 Mon, 3 – Tues, 4 – Wed., 5 Thu., 6 – Fri., 7 – Sat., 8 - All week's days, 0 – Clear all