AcceleRAID 160 Quick Installation Guide DB11-000021-00 First Edition 08P5510
Electromagnetic Compatibility Notices This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may cause radio interference.
Declaration of Conformity Per FCC Part 2, Section 2.1077(a) Manufacturer’s Name: LSI Logic Corporation Manufacturer’s Address: North American Headquarters Milpitas, CA USA Declares that the product: Product Name: AcceleRAID 160 PCI to Ultra 160 SCSI RAID Controller Model Number(s): A160-1-16NB Year of Manufacture: 2000 Conforms to the following Product Specification(s): FCC: CFR 47 Part 15, Subpart B, Section 15.107(e) and Section 15.109(g) Class B Digital Device tested per ANSI C63.
Declaration of Conformity Per 89\336\EEC Responsible Party Name: LSI Logic Corporation Address: North American Headquarters Milpitas, CA U.S.A.
Community of Europe CE mark is rated for the AceleRAID 160 as follows: CISPR 22 Radiated Emission EN55022, Generic immunity standard for the following: IEC 801-2 ESD, IEC 801-3 Radiated, and IEC 801-4 EFT/Burst Warning! This is a Class B product. In a residential environment this product may cause radio interference, in which case the user may be required to take adequate measures. Achtung! Dieses ist ein Gerät der Funkstörgrenzwertklasse B.
Underwriters Laboratories Statement and Warning
Proprietary Rights Notice This document contains proprietary information of LSI Logic Corporation. The information contained herein is not to be used by or disclosed to third parties without the express written permission of an officer of LSI Logic Corporation. Any product(s) described herein is/are a licensed product of LSI Logic Corporation. Document Description Document DB11-000021-00 First Edition.
Trademark Acknowledgments LSI Logic, the LSI Logic logo, MORE, Mylex, and SANmapping are trademarks or registered trademarks of LSI Logic Corporation. All other brand and product names may be trademarks of their respective companies.
Contents Hardware Installation Introduction ........................................................................................ 1-1 Performing an Installation .................................................................. 1-1 PCI Hot Plug .............................................................................. 1-1 Connectors, LEDs, and Jumpers ............................................... 1-2 Installing the AcceleRAID 160 into a Standard Chassis .............
2 AcceleRAID 160 Installation Guide
Hardware Installation Introduction The AcceleRAID 160 is a versatile single channel PCI to Ultra 160 SCSI, Low Voltage Differential (LVD) RAID controller with many possible hardware configurations. This quick installation guide assumes that the user is familiar with controller, disk drive, and RAID terminology. Performing an Installation ☛ Note A PCI 2.2 compliant slot is required to operate the AcceleRAID 160 controller. However, a PCI 2.1 compliant slot that supplies 5V power is acceptable.
Performing an Installation Connectors, LEDs, and Jumpers There is one external and one internal connector supported on the AcceleRAID 160 controller. The locations of the SCSI connectors are shown in Figure 1 and Figure 2 and are labeled as CH 0. There are two types of brackets: Standard PCI bracket (Figure 1) and Low Profile PCI bracket (Figure 2). CH 0 CH 0 Figure 1. AcceleRAID 160 Controller with Channel 0 Connectors and Standard PCI Bracket CH 0 CH 0 Figure 2.
Hardware Installation The front side of the controller has four LEDs that are illustrated in Figure 3 and described in Table 1. D1 D2 D3 D4 Figure 3. AcceleRAID 160 LEDs (front) Table 1. LED Descriptions (front) D1 FAIL (Processor Self Test) D2 TERM_LED (Terminator Enabled) D3 S0_LVD Mode D4 S0_SE (Single Ended) Mode Manual No.
Performing an Installation All the jumpers should normally be set to their default settings. Jumper locations are illustrated in Figure 4 and described in Table 2. J1 JP1 JP3 JP4 Figure 4. AcceleRAID 160 Jumper Locations Table 2.
Hardware Installation Installing the AcceleRAID 160 into a Standard Chassis If your system has a 2U chassis, please go to “Installing the AcceleRAID 160 into a 2U Chassis” on page 9. Caution Be sure to wear a ground wrist strap at all times. ☛ Note If the controller has the Low Profile Bracket attached, replace it with the Standard PCI bracket for this installation. 1.
Performing an Installation 3. Be sure termination is disabled on all SCSI drives connected to the controller. See the documentation that comes with your drives for instructions on how to do this. (Termination must be enabled on the last device, if not using an active terminator.) 4. Be sure that termination power is enabled on all SCSI drives connected to the controller. See the documentation that comes with your drives for instructions on how to do this. Connecting Internal SCSI Devices 5.
Hardware Installation Connecting External SCSI Devices 7. If you are installing external SCSI devices to the controller, individually or in an external drive cabinet, connect a cable, with the 68 pin VHDCI, to the external SCSI connector on the AcceleRAID 160 controller. Connect the other end of the cable connector to other devices or to a SAF-TE external drive cabinet, as required (see Figure 7). 8. External drive cabinets usually have termination built into the end of the SCSI bus.
Performing an Installation Connecting Both Internal and External SCSI Devices A combined installation showing internal and external devices with proper termination is illustrated in Figure 8. ☛ Note A combined configuration using both internal and external connectors works best with high quality cables. It is recommended that you use an Amphenol® Fast LVD and a Hitachi® twisted pair, flat cable in this unique setup. Figure 8.
Hardware Installation Installing the AcceleRAID 160 into a 2U Chassis You may need to check the manufacturer’s installation instructions for your particular 2U chassis. Caution Be sure to wear a ground wrist strap at all times. ☛ Note If the controller has the Standard PCI bracket attached, replace it with the Low Profile PCI bracket for this installation. 1. Choose the riser adapter with an available PCI slot. In this case, it is presented on an angle, as shown in Figure 9. 2.
Performing an Installation In the finished installation, the controller will be in a flat, horizontal position, as shown in Figure 10. 32-Bit PCI Low Profile Bracket AR160 Figure 10. AcceleRAID 160 Installed into a 2U Chassis 3. Set the SCSI ID on each internal drive to a unique address between 0 and 15, but do not use address 7, as it is reserved for the controller. See the documentation that comes with your drives for instructions on how to set the SCSI ID address.
Hardware Installation 4. Be sure termination is disabled on all SCSI drives connected to the controller. See the documentation that comes with your drives for instructions on how to do this. (Termination must be enabled on the last device, if not using an active terminator.) 5. Be sure that termination power is enabled on all SCSI drives connected to the controller. See the documentation that comes with your drives for instructions on how to do this. Connecting Internal SCSI Devices 6.
Performing an Installation Connecting External SCSI Devices 8. If you are installing external SCSI devices to the controller, individually or in an external drive cabinet, connect a cable, with the 68 pin VHDCI, to the external SCSI connector on the AcceleRAID 160 controller. Connect the other end of the cable connector to other devices or to a SAF-TE external drive cabinet, as required (see Figure 12). 9. External drive cabinets usually have termination built into the end of the SCSI bus.
Hardware Installation Connecting Both Internal and External SCSI Devices A combined installation showing internal and external devices with proper termination is illustrated in Figure 13. ☛ Note A combined configuration using both internal and external connectors works best with high quality cables. It is recommended that you use an Amphenol® Fast LVD and a Hitachi® twisted pair, flat cable in this unique setup. Figure 13.
What to Do Next User Manual.
LSI LOGIC CORPORATION SOFTWARE LICENSE AND WARRANTY POLICY Limited Warranty LSI warrants to the original purchaser of the product enclosed herein (“Customer”) that (a) for a period of three (3) years from the date of Customer’s purchase of the Product (excluding batteries and memory) (the “Product Warranty Period”), and (b) for a period of one (1) year from the date of purchase of the Product by Customer (the “Battery/Memory Warranty Period”), the batteries and memory included in the Product will (i) be fre
with LSI’s instructions and the terms of this Agreement, shipping costs to be borne by LSI, and (c) Customer has provided proof of purchase price and date for unregistered Product. LSI shall bear one-way shipping, packing and insurance costs and all other costs, excluding labor and parts, necessary to effectuate repair or replacement under this warranty. All Product repaired or replaced under this warranty shall be returned to Customer at Customer’s expense.
is a part of the Product (“LSI Software”) solely as part of the Product incorporated into the OEM Products that and not on a standalone basis.
Manual No. DB11-000021-00 08P5510 LSI Logic Corporation North American Headquarters Milpitas, CA 408.433.