User's Manual

Technical Specifications: (typical)
Characteristic Specification - description
RF transmission rate: 1.536 Mb/s
Ethernet Throughput: 1.01 Kb/s
Output power:
+20dBm (20 Watts EIRP used with 23dBi antennae AW23-5800)
Receive sensitivity:
-98dBm at 10e-4 BER (-121dBm with 23dBi antennae AW23-5800)
Radio link budget:
128dB with 5dBi antenna AW5-5800
164dB with 23dBi antennae AW23-5800
Line of Sight Range:
2 Miles Line of Sight with 5dBi antenna AW5-5800
40 miles Line of Sight with 23dBi antennae AW23-5800
Radio channels/bandwidth: 58 Non-overlapping with 2.0833MHz spacing and 1.75MHz occupied bandwidth.
Automatic frequency select: Yes – radio channel automatically selected and adaptively optimized
Connector types: RF RPSMA Female / Ethernet RJ45 10BaseT / Power Jack P5-2.1mm ID
Status LEDs: Power, Ethernet Link, RF RX, RF TX, 6/Channel and 6/Link Quality
Error correction technique: Sub-block error detection and retransmission.
Adjacent-band rejection: SAW receiver filter attenuates cellular and pager interference.
Regulator type: Switching Regulator
Power consumption:
Transmit - 1.8W
Receive – 1.0W
Voltage:
AC 12-24VAC at screw terminal
DC 6-48VDC at P5 power jack (center positive)
DC 6-48VDC at screw terminal (reverse polarity correction)
Power over Ethernet 9-48VDC over Ethernet – pairs 4/5 positive and7/8 ground.
Temperature range: -40°C to 70°C
Transmit current draw:
350mA at 6VDC
150mA at 12VDC
40mA at 48VDC
Size: 85x65x33mm
Product limited warranty:
This product is warranted to the original purchaser for normal use for a period of 180 days from the date of purchase. If a
defect covered under this warranty occurs Avalan will repair or replace the defective part, at its option, at no cost. This
warranty does not cover defects resulting from misuse or modification of the product.
Compliance Statement ( Part 15.19 )
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
Warning ( Part 15.21 )
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the
equipment.
RF Exposure ( OET Bulletin 65 )
To comply with FCC RF exposure requirements for mobile transmitting devices, this transmitter should only be used or installed at locations
where there is at least 20cm separation distance between the antenna and all persons.
Information to the User - Part 15.105 (b)
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
--Reorient or relocate the receiving antenna.
--Increase the separation between the equipment and receiver.
--Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
--Consult the dealer or an experienced radio/TV technician for help.