Owner`s manual

12 Stove Installation (for qualified installers only)
© Travis Industries 100-01260 4121205
Standard Ceiling
with a Factory
Built Chimney
Figure 7
Cathedral Ceiling
with a Factory
Built Chimney
Figure 8
Chimney Cap
(See the section "Chimney
Termination Requirements"
for more details)
Chimney Sections
Minimum Air Space to
Combustibles (See
Chimney Manufacturer's
Instructions)
Chimney Connector Sections
Follow the chimney
manufacturer's instructions
and clearances for roof
penetrations. A storm collar
and flashing are required
(some require a radiation
shield).
}
}
Follow the chimney
manufacturer's instructions
and clearances for floor
penetrations. A ceiling
support is required, an attic
insulation shield is required
where insulation is present.
Insulation
Minimum 15'
(4.57M)
Maximum 33'
(10.05M)
Must Maintain Stove
and Connector
Clearances
Floor
Protection
STOVE
Chimney Cap
(See the section "Chimney
Termination Requirements"
for more details)
Chimney Sections
Minimum Air Space to
Combustibles (See Chimney
Manufacturer's Instructions)
Follow the chimney
manufacturer's instructions
and clearances for roof
penetrations. A storm
collar, flashing, and
cathedral-style chimney
support are required
(some require a radiation
shield).
}
Minimum 15'
(4.57M)
Maximum 33'
(10.05M)
Must Maintain Stove
and Connector
Clearances
STOVE
Chimney Connector
Floor
Protection