Owner`s manual
Stove Installation (for qualified installers only) 13
© Travis Industries 100-01260 4121205
Exterior Factory
Built Chimney
NOTE:
Exterior chimneys are
subject to greater
moisture and creosote
accumulation due to the
lower temperatures. An
insulated chase will
reduce these
accumulations (the
proper clearances to the
chimney must be
maintained).
Figure 9
Hearth Stove
Positive
Connection
NOTE:
Most factory-built
chimney manufacturers
make stainless steel
chimney liners, either
flexible or rigid. This
provides a wide variety
of installation options.
Make sure to follow the
manufacturer's
instructions for
installation and support.
Figure 10
Chimney Cap
(See the section "Chimney
Termination Requirements"
for more details)
Chimney Sections
Minimum Air Space to
Combustibles (See
Chimney Manufacturer's
Instructions)
Chimney Connector
Follow the chimney
manufacturer's
instructions and
clearances for roof
penetrations. A storm
collar and flashing are
required (some
require a radiation
shield).
}
Must Maintain Stove
and Connector
Clearances
}
Follow the chimney
manufacturer's
instructions and
clearances for wall
penetrations. A
wall radiation shield
(thimble) is
required.
Optional
insulated
chase
Wall Bands
and
Supports
Insulated Tee
(with cleanout )
Must maintain
min.connector
clearance to
combustibles
Floor
Protection
Minimum 15' (4.57M)
Maximum 33' (10.05M)
STOVE
STOVE
Remove damper
or wire it open
Airtight Insulated
Clean-Out
Combustible
Mantle
NOTE: The entire fireplace and
chimney must be clean, undamaged,
and meet all local building codes
(UBC, etc.). Damage must be
repaired prior to installation. The
chimney must be 15' (4.57M) to 33'
(10.05M) tall.
The liner must be
stainless steel connector
or flexible vent. Follow
the liner manufacturer's
instructions for installation
and support.
Cap and flashing
prevents water from
entering
Must Maintain Stove
and Connector
Clearances
Floor
Protection
Must maintain
min.connector
clearance to
combustibles