Owner`s manual

Specifications 5
Travis Industries 4122104 93508117
Installation Options:
Freestanding Stove
Residential or Mobile Home
Horizontal or Vertical Vent
Features:
Ember Fyre Burner for "Wood Fire" Look
Works During Power Outages
Optional Thermostat or Remote Control
Variable-Rate Heat Output
Optional Blower
Heating Specifications:
Approximate Heating Capacity (in square feet)*......500 to 1,500 With Blower, 500 to 1200 Without
Maximum BTU Input Per Hour...............................31,000 (NG & LP)
Minimum BTU Output on Low (with blowers on) .....16,000 (NG) 20,100 (LP)
Steady State Efficiency............................................................................up to 86.1 %
AFUE......................................................................................................up to 67.2%
* Heating capacity will vary depending on the homes floor plan, degree of insulation, and the outside
temperature.
** Efficiency rating is a product of thermal efficiency rating determined under continuous operation independent
of installed system. To measure the net BTUs, multiply the BTU input by the efficiency percentage.
Dimensions:
Fuel:
Weight: 175 Lbs
Measure
Clearances from
the Stove Top
The starter section is
3/8" above the top.
17-5/8"
28"
22-1/2"
6"
This heater is shipped in natural gas (NG) configuration but may be converted to propane (LP) using the
included LP conversion kit. The sticker on top of the gas control valve will verify the correct fuel.
Electrical Specifications
Electrical Rating (with optional blower).........................115 Volts, 0.8 Amps, 60 Hz (92 watts on high)