Owner`s manual

12 Installation (for qualified installers only)
Travis Industries
100-01136 4040809
Approved Venting Configurations with a Horizontal Termination
If using a Snorkel Termination (14 or 36) add the snorkel height to the vertical height (snorkel
terminations are used primarily for basement installations).
The termination must fall within the shaded area shown in the chart. Use restrictor position #1.
Natural Gas (NG)
Installations
Propane (LP)
Installations
5 feet
0 feet
10' (max)
0 feet
5 feet
0 feet
0 feet
NOTE:
Horizontal sections
require a 1/4" rise every
12" of travel.
12 feet
(max)
NOTE:
A minimum 2 foot rise is required
directly off of the stove.
12 feet
(max)
5 feet
10' (max)
5 feet
Use Restrictor Position # 1
(all shaded areas)
5 feet
0 feet
11' (max)
0 feet
5 feet
0 feet
0 feet
NOTE:
Horizontal sections
require a 1/4" rise every
12" of travel.
NOTE:
A minimum 3 foot rise is required
directly off of the stove.
12 feet
(max)
11' (max)
5 feet
Use Restrictor Position # 1
(all shaded areas)
12 feet
(max)
5 feet