Owner`s manual
12 Installation   (for qualified installers only)
Travis Industries 100-01169_001 4050119
Approved Vent Configurations
Restrictor Position
• A restrictor is built into
the appliance to
control the flow rate of
exhaust gases. This
ensures proper flames
for the wide variety of
vent configurations.
Depending upon the
vent configuration, you
may be required to
adjust the restrictor
position. The charts
for approved vent
configurations
describe which
position the vent
restrictor must be in.
To Access the Restrictor
Use both hands to lift the stove 
top off the stove.
To Adjust the Restrictor
NOTE: 
The restrictor is 
shipped in 
position #1.
This restrictor is 
in position # 6
Lift the cotter pin out.
a
Slide the restrictor 
adjustment rod in.
b
Replace the cotter pin 
through the correct 
hole on the restrictor 
adjustment rod.
c
Restrictor 
Positions
# 2
# 4
# 6
# 3
# 5
# 1
Measuring Vent Lengths
Vent 
Horizontal 
Run
Vent Horizontal Run is 
measured from the start of 
the horizontal section to the 
end of the termination.
Vent Height is calculated to 
the top of the vent on 
horizontal terminations and 
to the top of the termination 
on vertical terminations.
Vent 
Height
Vertical Elbow
NOTE:
When a horizontal elbow (90° or 45°) is 
used, horizontal length is the sum of the 
two lengths (H1 + H2).
H1
H2
Horizontal 
Elbow
Vertical Elbow