Manual
Additional Controller Instructions
Setting the set point (desired temperature value)
1. Press SET for 1 second, the set temperature will start flashing after a few moments;
2. To increase or decrese the temperarture, use the UP or DOWN button;
3. Press SET to confirm new temperature.
Switching the device ON/OFF
Press UP for more than 3 seconds. The control and defrost algorithms are now displayed and the instrument
displays the message "OFF" alternating with the temperature read by the set probe.
Placing the device into a manual defrost
Press DOWN for more than 3 seconds (the defrost starts only if the temperature conditions are valid).
Placing the device into a continuous cycle
Press UP and DOWN together for more than 3 seconds.
Accessing and setting type F (frequent) and type C (configuration) parameters
1. Press SET for 3 seconds (the display will show "PS");
2. To access the type F and C parameter menu, press SET, enter the password "22" using UP/DOWN, press
SET to confirm;
3. Scroll inside the parameter menu using UP/DOWN;
4. To set the value of the parameter displayed, press SET, then UP/DOWN and finally SET to confirm the
changes (returning to the parameter menu).
To save all of the new values and exit the parameter menu, press SET for 3 seconds;
To exit the menu without saving the changed values (exit by timeout), do not press any button for at least
60 seconds.