5.4 Automatic operation test
Perform this inspection only if the AUTOMATIC
function is installed.
a) Press EMERGENCY STOP button on the
pendant control. Turn the HAND/AUTOM.
switch on the electrical control box to the right
to activate automatic operation. (Fig. 13 page
20)
b) Deactivate the EMERGENCY STOP button by
turning the button clockwise. (Check the
EMERGENCY STOP button fixed is deacti-
vated.) The service lift should stand still.
c) DO NOT try to activate the “automatic opera-
tion” switch.
d) If the trapped-Key interlock system is installed,
turn the trapped-key switch to ON. With the
doors closed, press the UP and DOWN
buttons. Neither upward nor downward
travel should be possible (Switch in pendant
control holder blocks the operation).
e) Press the EMERGENCY STOP button on the
pendant control.
f) Place the pendant control in its holder so it is
operational from the outside.
g) Leave the cabin and close the door.
h) Deactivate the EMERGENCY STOP button.
The service lift should stand still.
i) Press the UP button. The lift should travel
upwards.
j) Press the EMERGENCY STOP button. The lift
stops.
k) Turn the EMERGENCY STOP button clockwise
and press the DOWN button. The service lift
should travel downwards until the EMERGEN-
CY STOP bottom stops the service lift.
l) Remove the pendant control from holder.
m) Return the HAND/AUTOM. button to HAND.
n) Check that the UP and DOWN buttons work
again.
5.5 Remote operation test
Perform this inspection only if the remote control
function is installed.
a) Set the electrical control box switch HAND/
AUTOM to AUTOM (fig 7 a).
b) On top of the remote operation receiver switch
the device on (g 7 b).
c) Press the up arrow on the remote operation
transmitter. The service lift should ascend.
d) Press the down arrow on the remote operation
transmitter. The service lift should descend.
e) Once the test is complete, switch the remote
operation function off.
5.6 Safety gripping device
a) Engage the safety brake by pressing the
safety brake stop button - the handle should
jump to the “ON” position (Fig. 8 section 4.7).
b) Reopen the safety brake by pressing down on
the lever – the lever must engage.
c) During operation, regularly monitor the centrifu-
gal force regulator relay’s rotation by looking
through the window.
5.7 Wires and suspension
a) During operation: Check the lifting and safe-
ty wires for free passage through hoist and
safety gripping device.
b) When the lift is at the top landing, inspect the
wire attachment and all the building
sections that suspend the lift.
Fig. 13b
Emergency
stop button
Automatic
operation
switch