2.8 Adjustment of the safe-zone plates
(Full open door lifts)
2.9 Adjustment of top stop disc
The service lift door should be able to be opened
whenever the cabin is in alignment with the
platform (tolerance ± 100 mm).
The safe-zone plate is adjusted in relation to the
platform position switchxed on the cabin (see
Fig. 15).
The top stop disc is adjusted so the top limit stop
switch stops the lift in alignment with the top
landing platform, however at least 200 mm before
contact with the wire thimble.
The emergency limit stop switch is a backup. It is
adjusted so it stops the lift in case the operation
limit stop switch fails (See Fig. 10 on page 19 of
the User’s Manual).
The emergency limit stop shuts off the control, just
like an emergency stop. If the emergency limit stop
is activated, lowering can only be done manually
as described on page 23 of the Users Manual.
Manual lowering will activate the lift again.
3. Danger zone! sticker
Mount the “Danger Zone” sticker in the tower
behind the lift and the yellow marking ribbon on
theoor. Make sure the wall and platform are
clean and dry before attaching the sticker and
ribbon.
DANGER!
Make sure that nobody is exposed to danger
below the service lift, for instance from falling
parts.
Suitable measures: Pent roof or barriers.
The service lift is now ready for use.
Prior to use, however, carry
out the inspection specified
in Installation Guide section 5!
4. Disassembling
Disassemble in reverse order and dispose of in
accordance with local authority regulations.
Fig. 15