User's Guide

5-8 User interface description
Internet BWA System 3200 NTXXXXXX Rel 3.0 Draft October 2000
Blk Error Cnt
To view the cumulative block error count from the FEC decoder. At this
parameter, the system first reads the counter and then clears it.
Values:
Sum Alarms
To view all active alarms. You can scroll through each active alarm. Refer to
Chapter 4, “Trouble clearing procedures” for the alarm definitions.
Values: Temperature overrange
Temperature underrange
Tx low output power
Rx frame loss
Low RSL
AFC loop OOL
AGC loop OOL
Tx synthesizer OOL
Rx synthesizer OOL
FAW error alarm
Data link alarm
Tributary 1 Tx LOS
Tributary 2 Tx LOS
Tributary 3 Tx LOS
Tributary 4 Tx LOS
Tributary 1 Rx AIS
Tributary 2 Rx AIS
Tributary 3 Rx AIS
Tributary 4 Rx AIS
Inventory submenu
This section lists the parameters within the “Inventory” submenu of the “Near
Radio” menu.
PEC
Displays the ODU PEC code
Product rel ver
Displays the ODU release version
Serial No.
Displays the ODU serial number
ODU SW
Displays the version number of the ODU controller software . The number has
an implied decimal point before the last two digits (for example: 110 = version
1.10)