Part No.
Copyright © 2000 Nortel Networks All rights reserved. December 2000. The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must take full responsibility for their applications of any products specified in this document. The information in this document is proprietary to Nortel Networks NA Inc.
Japan/Nippon Requirements Only Voluntary Control Council for Interference (VCCI) Statement Taiwan Requirements Bureau of Standards, Metrology and Inspection (BSMI) Statement Canada Requirements Only Canadian Department of Communications Radio Interference Regulations This digital apparatus (BN router) does not exceed the Class A limits for radio-noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications.
Canada Requirements Only (continued) Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.
FCC Part 68 Compliance Statement This equipment complies with Part 68 of FCC Rules. All direct connections to telephone network lines must be made using standard plugs and jacks compliant with FCC Part 68. Please note the following: 1. You are required to request service from the telephone company before you connect the unit to a network.
Nortel Networks NA Inc. Software License Agreement NOTICE: Please carefully read this license agreement before copying or using the accompanying software or installing the hardware unit with pre-enabled software (each of which is referred to as “Software” in this Agreement). BY COPYING OR USING THE SOFTWARE, YOU ACCEPT ALL OF THE TERMS AND CONDITIONS OF THIS LICENSE AGREEMENT. THE TERMS EXPRESSED IN THIS AGREEMENT ARE THE ONLY TERMS UNDER WHICH NORTEL NETWORKS WILL PERMIT YOU TO USE THE SOFTWARE.
for the security of its own data and information and for maintaining adequate procedures apart from the Software to reconstruct lost or altered files, data, or programs. 4. Limitation of liability.
Contents Preface Before You Begin ............................................................................................................. xv How to Use This Supplement .......................................................................................... xv Text Conventions .............................................................................................................xvi Acronyms ........................................................................................................
Chapter 4 Using the 56/64K DSU/CSU Adapter Module in a Passport 2430 Multiservice Access Switch Attaching Cables ............................................................................................................4-1 Completing Software Configuration ................................................................................4-2 Interpreting LEDs ...........................................................................................................
Figures Figure 1-1. 56/64K DSU/CSU Adapter Module Connector on an AN or 12-Port ANH 1-2 Figure 1-2. 56/64K DSU/CSU Adapter Module Connector on an 8-Port ANH ...........1-2 Figure 1-3. 56/64K DSU/CSU Adapter Module LEDs ................................................1-4 Figure 2-1. ARN 56/64K DSU/CSU Adapter Module (Slot 2) .....................................2-2 Figure 2-2. ARN 56/64K DSU/CSU Adapter Module LEDs ........................................2-4 Figure 3-1.
Tables Table 1-1. PROM Diagnostic and Boot Code for AN/ANH Routers ..........................1-1 Table 1-2. 56/64K DSU/CSU Adapter Module LEDs ................................................1-4 Table 2-1. PROM Diagnostic and Boot Code for ARN Routers ................................2-1 Table 2-2. 56/64K DSU/CSU Adapter Module LEDs ................................................2-4 Table 3-1. WAN Adapter Combinations ....................................................................
Preface The 56/64K DSU/CSU adapter module provides an interface for direct connection to Telco leased-line circuits. The 56/64K DSU/CSU adapter module provides an integrated DSU/CSU to directly connect to either 64 Kb/s Clear Channel or 56 Kb/s DDS services.
56/64K DSU/CSU Adapter Module Supplement Text Conventions This guide uses the following text conventions: bold text Indicates command names and options and text that you need to enter. Example: Enter show ip {alerts | routes}. Example: Use the dinfo command. italic text Indicates file and directory names, new terms, book titles, and variables in command syntax descriptions. Where a variable is two or more words, the words are connected by an underscore.
Preface Hard-Copy Technical Manuals You can print selected technical manuals and release notes free, directly from the Internet. Go to the support.baynetworks.com/library/tpubs/ URL. Find the product for which you need documentation. Then locate the specific category and model or version for your hardware or software product. Use Adobe Acrobat Reader to open the manuals and release notes, search for the sections you need, and print them on most standard printers. Go to Adobe Systems at www.adobe.
Chapter 1 Using the 56/64K DSU/CSU Adapter Module in an Access Node (AN) or Access Node Hub (ANH) Router This chapter supplements Installing an Adapter Module in an AN or ANH Router. Follow the hardware installation steps in that manual, then refer to this document for information specific to the 56/64K DSU/CSU adapter module. Verifying AN/ANH Router Requirements Table 1-1 shows the version and location of required programmable read-only memory (PROM) code for the 56/64K DSU/CSU adapter module. Table 1-1.
56/64K DSU/CSU Adapter Module Supplement • AN or 12-port ANH -- the back-panel adapter module slot (Figure 1-1). See Installing an Adapter Module in an AN or ANH Router. • 8-port ANH -- the back-panel COM3 slot (Figure 1-2). See Installing an Adapter Module in an AN or ANH Router. UL UL XCVR UTP TX RX CL COM 2 CONSOLE COM 1 100-240V 50-60 Hz 1.0-0.5A RST RLSD1 RLSD2 DDS 56K/64K DSU/CSU Tx CD Rx Test Complies with FCC Rules Part 66 Reg.
Using the 56/64K DSU/CSU Adapter Module in an Access Node (AN) or Access Node Hub (ANH) Completing Software Configuration Once you have successfully installed the adapter module, complete the following software configuration tasks using instructions found in your BayRS documentation: Configuration Task Location of Instructions Connect the AN/ANH to the network.
56/64K DSU/CSU Adapter Module Supplement Interpreting LEDs The 56/64K DSU/CSU LEDs (Figure 1-3) will blink on and off during diagnostic testing, but they will not stay on to indicate data transfer until you have configured and enabled software services. DDS 56K/64K DSU/CSU Tx CD Rx Test Complies with FCC Rules Part 68 Reg. Number 6LW USA-27823-DE-N ARN0105A Figure 1-3. 56/64K DSU/CSU Adapter Module LEDs Table 1-2 describes the function of each 56/64K DSU/CSU LED. Table 1-2.
Chapter 2 Using the 56/64K DSU/CSU Adapter Module in a Passport ARN Router This chapter supplements Installing and Operating Passport ARN Routers (Chapter 4, “Installing a WAN Adapter Module”). Follow the hardware installation steps in that manual, then refer to this document for information specific to the 56/64K DSU/CSU adapter module. Verifying ARN Router Requirements Table 2-1 shows the version and location of required programmable read-only memory (PROM) code for the 56/64K DSU/CSU adapter module.
56/64K DSU/CSU Adapter Module Supplement Attaching Cables Connect the Telco service cable to the RJ-48C connector on the installed 56/64K DSU/CSU adapter module. You install the adapter module in one of the two front-panel WAN adapter module slots (Figure 2-1). See Installing and Operating Passport ARN Routers for complete installation instructions.
Using the 56/64K DSU/CSU Adapter Module in a Passport ARN Router Completing Software Configuration Once you have successfully installed the adapter module, complete the following software configuration tasks using instructions found in your BayRS documentation: Configuration Task Location of Instructions Connect the ARN to the network.
56/64K DSU/CSU Adapter Module Supplement Interpreting LEDs The 56/64K DSU/CSU LEDs (Figure 2-2) will blink on and off during diagnostic testing, but they will not stay on to indicate data transfer until you have configured and enabled software services. DDS 56K/64K DSU/CSU Tx CD Rx Test Complies with FCC Rules Part 68 Reg. Number 6LW USA-27823-DE-N ARN0105A Figure 2-2. ARN 56/64K DSU/CSU Adapter Module LEDs Table 2-2 describes the function of each 56/64K DSU/CSU LED. Table 2-2.
Chapter 3 Using the 56/64K DSU/CSU Adapter Module in a Passport 5430 Multiservice Access Switch This chapter supplements Installing and Operating the Passport 5430 Multiservice Access Switch. Follow the hardware installation steps in Installing and Operating the Passport 5430 Multiservice Access Switch, then refer to this document for information specific to the 56/64K DSU/CSU adapter module.
56/64K DSU/CSU Adapter Module Supplement If you use two ISDN BRI adapters and no other WAN adapter module, both ISDN BRI modules have two circuits available for use and therefore each can bring up two B channels plus one D channel. If you use two ISDN BRI adapters and another WAN adapter module, the number of circuits available to WAN adapters stays the same while the total number needed by the WAN adapters increases by one.
Using the 56/64K DSU/CSU Adapter Module in a Passport 5430 Multiservice Access Switch Attaching Cables Connect the Telco service cable to the RJ-48C connector on the installed 56/64K DSU/CSU adapter module. You install the adapter module in one of the three front-panel module slots (Figure 3-1). See Installing and Operating the Passport 5430 Multiservice Access Switch for complete installation instructions.
56/64K DSU/CSU Adapter Module Supplement Completing Software Configuration Once you have successfully installed the adapter module, complete the following software configuration tasks using instructions found in your BayRS documentation: Configuration Task Location of Instructions Modify the Passport 5430 configuration file to add the 56/64K DSU/CSU module and enable default software services.
Using the 56/64K DSU/CSU Adapter Module in a Passport 5430 Multiservice Access Switch Interpreting LEDs The 56/64K DSU/CSU LEDs (Figure 3-2) will blink on and off during diagnostic testing, but they will not stay on to indicate data transfer until you have configured and enabled software services. DDS 56K/64K DSU/CSU Tx CD Rx Test Complies with FCC Rules Part 68 Reg. Number 6LW USA-27823-DE-N ARN0105A Figure 3-2.
Chapter 4 Using the 56/64K DSU/CSU Adapter Module in a Passport 2430 Multiservice Access Switch This chapter supplements Installing and Operating the Passport 2430 Multiservice Access Switch. Follow the hardware installation steps in that manual, then refer to this document for information specific to the 56/64K DSU/CSU adapter module. Attaching Cables Connect the Telco service cable to the RJ-48C connector on the installed 56/64K DSU/CSU adapter module.
56/64K DSU/CSU Adapter Module Supplement 1 DDS 56K/64K DSU/CSU To Digital line wall jack VLK0027A Figure 4-1. 56/64K DSU/CSU Adapter Module Connector on a Passport 2430 Completing Software Configuration Once you have successfully installed the adapter module, complete the following software configuration tasks using instructions found in your BayRS documentation: Configuration Task Location of Instructions Connect the Passport 2430 to the network.
Using the 56/64K DSU/CSU Adapter Module in a Passport 2430 Multiservice Access Switch Interpreting LEDs The 56/64K DSU/CSU LEDs (Figure 4-2) will blink on and off during diagnostic testing, but they will not stay on to indicate data transfer until you have configured and enabled software services. DDS 56K/64K DSU/CSU Tx CD Rx Test Complies with FCC Rules Part 68 Reg. Number 6LW USA-27823-DE-N ARN0105A Figure 4-2.