S-Registers
C-15
Register: S8
Description: This S-register controls the duration of delay for pauses
for voice calls.
Range of Values: Value may be 000 through 255 seconds; factory-default
value is 2 seconds.
Storable: no
Comments: The 8400B Plus Data Module supports the comma dial
modifier to provide pauses in the dialing process for a
voice call. (The comma is sent to the switch for data
calls.)
See Also: The comma (,) dial modifier on page B-6 and "Dialing
Pause" on page 3-19.
Table C-1. Labels Used in S-Registers
Label Description
020709_2.book Page 15 Friday, April 23, 1999 5:39 AM