8400B Plus Data Module User’s Guide
555-020-709
Issue 2
November 1996
S-Registers
C-31
Register: S25
Description: The value in this S-register determines how long a
change of state (OFF to ON or ON to OFF) on the DTR
lead must persist before it is acknowledged. If the
change of state persists for a shorter time than is
specified in S-register S25, it is ignored.
Range of Values: Value may be 000 through 255 hundreds of a second
(0.01 second). The factory-default value is 5 (0.05
second).
Storable: yes
Comments: none
See Also: The &D command on page A-23.
Table C-1. Labels Used in S-Registers
Label Description
020709_2.book Page 31 Friday, April 23, 1999 5:39 AM