AT Command Set
A-18
Command: V
Function: Select format for result codes.
Type: configuration
Arguments: No argument or an argument of 0 causes the 8400B
Plus Data Module to return the short form or numeric
result codes; an argument of 1 causes the 8400B Plus
Data Module to return the verbose form or text message
result codes. The factory-default setting is the verbose
form.
S-Register: Bit 3 of S14 is set according to the argument used with
the V command.
Example: ATV
Comments: The example would set the short form or numeric result
code format.
See Also: The Q command on page A-15
, the X command on
page A-19
, S-register S14 on page C-20, and the result
codes on page E-7
.
Table A-1. Accepted AT Command Labels
Label Description
ENTER