Release Notes
Table Of Contents
- Release Notes for the Business Policy Switch 2000 Software Version 1.1
- Introduction
- Related publications
- New features and enhancements
- Compatibility with BayStack 450 Switch software version4.0
- QoS traffic policing
- EAPOL-based security
- Introduction
- EAPOL-based security example
- Overview and terms
- EAPOL dynamic VLAN assignment
- Setting up the Authentication server
- Authentication process
- System requirements
- EAPOL-based security configuration rules
- RADIUS-based network security
- Configuring EAPOL using CI menus
- Configuring EAPOL using JDM
- Configuring EAPOL using the Web-based management system
- Support for the GBIC MDA
- Automatic PVID
- Tabular port statistics
- Ability to ping
- Improved STP Fast Learning Mode
- BootP menu item for a stack of only BPS 2000 switches
- Additional Web-based management operation
- Resolved issues
- Known issues
- Known limitations
12
210676-C
Table 1 describes the fields in the Meter Creation area, which you use to set
new meters.
8 View created meters in the Meter Table.
Table 2 describes the fields in the Meter Table.
Table 1 Meter Creation fields
Field Description
Name Enter the name for the filter you are creating.
Data Specification Choose from the list to install a filter with:
• No Meter Data
• Metered Data
NOTE: When you choose No Meter Data, do not complete
the Committed Rate, Committed Burst Size, or Out-Profile
Action fields in the box.
Committed Rate Use this field only if you specified metered data for this
filter (refer to Data Specification, above). Enter the
Committed Rate in kbits/second here. You can enter from
13 kbits/second to 1,700,000 kbits/second.
Committed Burst Size Use this field only if you specified metered data for this
filter (refer to Data Specification, above). Enter the
Committed Burst Size in bytes here. You can enter from
2,047 bytes to 131,071 bytes.
In-Profile Action Choose from the list the action you previously created
(using the Actions page).
Out-Profile Action Use this field only if you specified metered data for this
filter (refer to Data Specification, above). Choose from the
list the action you previously created (using the Actions
page).
Table 2 Meter Table fields
Field Description
Action Deletes that meter.
Name Displays the name of the filter.
Instance Displays the generated Meter Table index.
Data Specification Displays whether the filter is set up with Metered Data or
No Meter Data.
Committed Rate Displays the specified bandwidth, in kbits per second.