User's Manual
Enhanced DATA VLAN 477
was manually configured in the DATA VLAN field. Any packet arriving
on the PC port which is already tagged is dropped.
•
DATA VLAN enabled—all traffic is forwarded to the PC port based on
a review of the MAC address and the 802.1Q value that was manually
configured in the DATA VLAN field. Traffic is forwarded out the PC port
only if the packets contain the DATA VLAN tag. Untagged traffic and
traffic without the DATA VLAN tag is dropped.
DATA (PC Port) VLAN Tag Stripping
DATA VLAN Tag Stripping can be configured in the Network Configuration
menu. To enable DATA VLAN Tag Stripping, select the PC-Port Untag
All check box, DATA VLAN Tag Stripping can be enabled or disabled
independent of enabling VLAN support on the PC Port.
If the DATA VLAN Tag Stripping is disabled, the packet is sent to the PC
Port unmodified. If the DATA VLAN Tag Stripping is enabled, the 802.1Q
header if one exists, is removed from the packet before the packet is
forwarded to the PC port.
During manual configuration, if DATA VLAN is enabled by configuring a
VLAN ID, the PC-Port Untag All check box is selected and is enabled by
default. By default, the egress tag is stripped. To manually override this
setting and disable egress stripping, clear the PC-Port Untag All check
box.
If DATA VLAN is not enabled during manual configuration, the PC-Port
Untag All check box is not selected. By default, the ingress tag is not
stripped. To manually override this setting and enable ingress stripping,
select the PC-Port Untag All check box.
Nortel Communication Server 1000
IP Phones Fundamentals
NN43001-368 02.07
5 February 2009
Copyright © 2003-2009 Nortel Networks
.