User's Manual
676 Power requirements and environmental specifications
Table 151 "Power requirements for IP Phones using Power over Ethernet
Classification 2" (page 676) provides power requirements for IP Phones,
which use Power over Ethernet Classification 2.
Table 151
Power requirements for IP Phones using Power over Ethernet Classification 2
IP Phone
Product
Code
Class
Max.
Power
Typical
Power
Storage
Temp
Storage
Humidit
y
Oper.Temp
Oper.
Humidity
2001 NTDU90xx 2 -40 to 70 5 to 40 5 to 95%
2002 NTDU91xx 2 -40 to 70 5 to 40 5 to 95%
2004 NTDU92xx 2 -40 to 70 5 to 40 5 to 95%
2007 3 17 7 -20 to 70
2007
2033
1210 NTYS18xx 2 4.6 3.2 -40 to 70 5 to 40 5 to 95%
1220 NTYS19xx 2 4.6 3.2 -40 to 70 5 to 40 5 to 95%
1230 NTYS20xx 2 4.6 3.2 -40 to 70 5 to 40 5 to 95%
1110 2 -40 to 70 5 to 40 5 to 95%
1120E 3 -40 to 70 5 to 40 5 to 95%
1120E 3 -40 to 70 5 to 40 5 to 95%
1120E NTYS03xEE
6
2 -40 to 70 5 to 40 5 to 95%
1140E 3 -40 to 70 5 to 40 5 to 95%
1140E 3 -40 to 70 5 to 40 5 to 95%
1140E NTYS05xEE
6
2 -40 to 70
1150E 2 -40 to 70 5 to 40 5 to 95%
1165E NTYS07xxE
6
2 6.49 3.5 -30 to 70 < 90% 5 to 40 5 to 80%
Table 152 "Power requirements for IP Phones using Power over Ethernet
Classification 3" (page 676) provides power requirements for IP Phones,
which use Power over Ethernet Classification 3.
Table 152
Power requirements for IP Phones using Power over Ethernet Classification 3
IP Phone
Product Code
Maximum Load Normal Load
2007
NTDUxxxx 12.0 W 7.0 W
1120E NTYSxxxx 9.6 W 6.0 W
Nortel Communication Server 1000
IP Phones Fundamentals
NN43001-368 05.06 30 April 2010