User's Manual

234 Table: eASYNC
eASYNC_Type_str
This field specifies the provider type, which can be either PAGING or SMS.
Currently there is support for PAGING with provider BELGACOM, and
SMS with provider PROXIMUS or KPN. Support for other providers and
types can be added in future releases, or can be built on request.
For example:
PAGING (requires the field eASYNC_Provider_str to equal
BELGACOM)
SMS (requires the field eASYNC_Provider_str to equal PROXIMUS)
SMS (requires the field eASYNC_Provider_str to equal KPN)
eASYNC_Provider_str
This field specifies the provider, which is related to the type specified in the
eASYNC_Type_str field, which can be either PAGING or SMS. Currently
there is support for PAGING with provider BELGACOM and SMS with
provider PROXIMUS and KPN. Support for other providers and types can
be added in future releases, or can be built on request.
For example:
BELGACOM (required when eASYNC_Type_str is PAGING)
PROXIMUS or KPN (required when eASYNC_Type_str is SMS)
eASYNC_Password_str
This field specifies the password to access the service provider. This field
is only relevant when eASYNC_Type_str is SMS.
For the provider PROXIMUS, you must enter a password (proximus) in the
initialization string. In this field, you can enter the password.
For KPN, no password is required (eASYNC_Password_str = *NONE).
The default value is *NONE, and means that no password is required.
Note: Password is case-sensitive.
Example of initialization string for provider PROXIMUS, password
proximus:
01/00121/O/01/32475353215//proximus/3/
534D5320746F2050726F78696D
7573207769746820534F50484F204D657373656E676572404E6574/A3
Nortel Communication Server 1000
DECT Messenger Installation and Commissioning — Book 2
NN43120-301 02.01 4 June 2010
Copyright © 2003-2010 Nortel Networks. All Rights Reserved.
.