310 Table: eIO_DO
An authorized of an entry typically found in this field is as follows: 01
eIODO_Contact_str
This value refers to each individual contact, and is specified in the
FieldPoint Explorer. Valid values are in the range between 01 and 16
for the currently supported FP-DO-401. Note contact numbers start with
01 and are incremented by one. You must specify the leading 0 in the
numbering (do not specify 1, but specify instead 01). Note that some
peripherals of National Instruments include labels and documentations
where contacts start numbering at 0 up to 15, whereas eIO starts at 01
up to 16.
An authorized of an entry typically found in this field is as follows: 01
eIODO_Seconds_n
When the eKERNEL sends a <msgrqs> to change the state of the contact,
the eIO performs the requested operation.
The state of the discrete output changes from 0 to 1.
The value eIODO_Seconds_n specifies the number of seconds a digital
output remains activated. For instance, if the value 5 is specified, the
signal remains 1 for 5 seconds, then the signal drops again to 0.
The special value triggers the contact for a very small amount of time. The
value immediately returns to 0. In many environments the signal is too
short to steer an external peripheral.
A typical value is 5 so that the discrete contact is activated for 5 seconds
and then returns to an idle state.
An authorized of an entry typically found in this field is as follows: 5
eIODO_Comments_str
This field can contain remarks from the administrator. The value is
informational only, and does not affect processing.
Table 26 "eIO_DO sample data" (page 310) provides sample eIO_DO
module table data.
Table 26
eIO_DO sample data
Site
Area Module
Contact Seconds Comments
1 1 03 01
5
1 1 03 02
5