User's Manual

377
.
Table: eKERNEL_SITE
eKERNEL_SITE parameters
CFG_site_id_n
This field specifies the site ID. In DECT Messenger, a site is the place
where the eKERNEL module runs. Each eKERNEL instance has an
appropriate database Messenger_CFG and Messenger_DATA. Note that
a site can span multiple physical areas spread over multiple locations,
and still being considered as one single site, because there is only one
eKERNEL running.
Note: The field is numeric. Nortel recommends using site 1 for the
first site, and increase the value by one for other sites that are added
in time. If two sites have neither communications nor any interference,
both sites can in theory use the same number. However, if integration is
planned, give different sites different numbers.
Nortel Communication Server 1000
DECT Messenger Installation and Commissioning — Book 2
NN43120-301 02.01 4 June 2010