Administrator's Guide

Multifrequency-Signaling-Related System Parameters
Issue 5 October 2002 1049555-233-506
Maximum Resent Requests
MF Signaling Intercept Treatment - Incoming
MF Signaling Intercept Treatment - Outgoing
Displays when the Outgoing Call Type field is group-ii-mfc.
MFE Type
This field only appears when Incoming Call Type is mfe.
Valid
entries Usage
1
to 99 Enter the threshold number of resend type MFC signals your
switch accepts during an outgoing call.
1
The call is dropped if one resend signal is received.
blank An unlimited number of resend requests is allowed.
Valid entries Usage
y
Send the group B signal for the intercept to the CO and play
intercept tone on the trunk.
n Use normal DID/TIE/ISDN intercept treatment.
Valid entries Usage
announcement
Plays a recorded announcement for outgoing calls that
cannot be completed as dialed. You select and record the
message.
Enter the extension number for the announcement in the
associated field.
tone
Plays intercept tone for outgoing calls that cannot be
completed as dialed.
Valid entries Usage
2/5
Determines which public signaling the switch will use.
2/6