Administrator's Guide

Signaling Group
Issue 5 October 2002 1119555-233-506
LRQ Required
Appears when the Group Type field is h.323.
Signaling Mode
A display-only field that appears when the Group Type field is atm. This field
always sets to
isdn-pri.
Circuit Type
Appears when the Group Type field is atm.
RRQ Required
Appears when the Group Type field is h.323. This field specifies the signaling
group that serves as a gateway rather than gatekeeper.
Idle Code
Appears when the Group Type field is atm.
Connect
Appears when the Group Type field is atm.
Valid entries Usage
y/n
Enter n if the far-end switch is an Avaya MultiVantage. Enter
y if the far-end switch is a non-DEFINITY and requires a
location request to obtain a signaling address in its signaling
protocol. If
y, Calls Share IP Signaling Connection must be
n.
Valid display Usage
T1
Results in page 2 displaying 24 channels.
E1
Results in page 2 displaying 31 channels.
Valid display Usage
y/n
Displays y if the signaling group serves a remote office
(gateway). Displays
n if the signaling group serves a
gatekeeper.
Valid entries Usage
0, 1