Administrator's Guide

Setting up remote office
Issue 5 October 2002 123555-233-506
Instructions
Set up the signaling group for remote office:
1. Type
add signaling-group and the number of the group you want to add.
The signaling group screen appears.
2. In the Group Type field, type
H.323.
3. In the Remote Office field, type
y.
4. In the Trunk Group for Channel Selection, type the number of the trunk
you set up for the remote office.
5. In the Near-end Node Name, identify the node name assigned to the CLAN
that supports the R300.
6. In the Far-end Node Name, identify the node name assigned to the CLAN
that supports the R300.
7. In the Near-end Listen port, type a port number in the 5000-9999 range.
8. In the Far-end Listen Port field, type
1720. See DEFINITY® Enterprise
Communications Server Release 1.1 Getting Started with the Avaya R300
Remote Office Communicator for more details.
9. In the RRQ field, type
y.
10. Tab to the Direct IP-IP Audio Connection field on another page of this
screen and type
y.
11. Press ENTER to save your changes.
add signaling-group 6 Page 1 of 5
SIGNALING GROUP
Group Number 6 Group Type: H.323
Remote Office? y Max Number of NCA TSC: ___
Max number of CA TSC: ___
Trunk Group for NCA TSC: ___
Trunk Group for Channel Selection: 6
Supplementary Service Protocol: _
Near-end Node Name: clan Far-end Node Name: remote office 6
Near-end Listen Port: 5001 Far-end Listen Port:5055
LRQ Required? _ Calls Share IP Signaling Connection? _
RRQ Required? y
Bypass If IP Threshold Exceeded? _
Interworking Message: ________