Administrator's Guide

Screen reference
555-233-5061266 Issue 5 October 2002
.
This field appears when the out side of the entry in the Trunk Type (in/out) field
is
/wink or /delay and the Group Type is tie, access, aplt, dmi-bos, rlt, or
tandem. The setting in this field only affects trunks administered to ports on
TN760C (vintage 4 or later), TN767, TN464C (or later), and TN2242 circuit
packs. If the trunk group also contains trunks assigned to ports on other types of
circuit packs, those trunks are unaffected.
Field descriptions for page 2
The figure below shows a common configuration for page 2 of the Trunk Group
screen when the Group Type field is
co. This screen is only an example, and the
fields shown below may change or disappear according to specific field settings.
Setting of the Trunk
Type (in/out) field What the Wink Timer field sets
/wink
Maximum duration of the wink signal
(wait-for-wink-to-end)
/delay
Maximum interval after trunk seizure for the wink to
begin (wait-for-wink-to-start)
Valid entries Usage
300
to 5000
in increments
of 50
In general, Avaya recommends that you not change this field.
If you do, remember that your switchs timing must be
compatible with the timing on the far-end switch.