Glare
This field is only administrable if the Trunk Type field is cont and the trunk group
Direction field is
two-way or outgoing. Only TN2140 ports receive this timer.
Incoming Dial Guard (msec)
NOTE:
This timer is never sent to TN429 ports.
Incoming Disconnect (msec)
The field appears only when the Direction field is incoming or two-way and the
Trunk Type field is either blank or
cont.
Incoming Disconnect Send (msec)
This field is only administrable if the Trunk Type field is dis and the trunk group
Direction field is
incoming or two-way. Only TN2140 ports receive this timer.
Valid entries Usage
40
to 100 in
increments of
10
Enter the minimum acceptable interval (in msec) between the
moment your switch sends an outgoing seizure and the
moment it receives a seizure acknowledgment. If
acknowledgment is received before the timer expires, glare is
assumed.
Valid entries Usage
10
to 2550 in
increments of
10
Enter the minimum acceptable interval between the detection
of an incoming seizure and the acceptance of the first digit.
The switch will not accept digits before this timer expires.
Valid entries Usage
50
to 2550 in
increments of
10
Enter the minimum valid duration of a disconnect signal for
an incoming call. The switch will not recognize shorter
disconnect signals. This field cannot be blank. For Brazil
pulsed E&M signaling, use
600.
Valid entries Usage
500
to 1200
in increments
of 100
Enter the duration of the backward release signal your switch
sends at the end of an incoming call.