Administrator's Guide

Screen reference
555-233-5061282 Issue 5 October 2002
Normal Outgoing Seize Send (msec)
This field appears only if the Trunk Type field is dis and the trunk group Direction
field is
two-way or outgoing. Only TN2140 ports receive this timer.
Outgoing Dial Guard (msec)
Outgoing Disconnect (msec)
Outgoing Disconnect Send (msec)
This field is administrable only if the Trunk Type field is dis and the trunk group
Direction field is
two-way or outgoing. Only TN2140 ports receive this timer.
Valid entries Usage
10
to 990 in
increments of
10
Enter the duration of the signal your switch sends for an
outgoing seizure.
Valid entries Usage
100
to 25500
in increments
of 100
Enter the minimum interval between seizure
acknowledgment of a trunk and the outpulsing of digits. This
field cannot be blank. For trunks that do not provide seizure
acknowledgment, the timer specifies the minimum time
between seizure and the outpulsing of digits. Any digit the
caller dials after they lift the receiver, but before the timer
expires, is not outpulsed until the timer expires.
Valid entries Usage
50
to 2550 in
increments of
10
Enter the minimum valid duration of a disconnect signal for
an outgoing call. The switch will not recognize shorter
disconnect signals. This field cannot be blank. This timer
begins timing when a disconnect signal is detected on an
outgoing call and resets when the signal is no longer
detected. If the timer expires, the trunk drops. For Brazil
pulsed E&M signaling, use
600.
Valid entries Usage
100
to 9900
in increments
of 100
Enter the duration of the forward release signal your switch
sends at the end of outgoing calls.