Administrator's Guide

Screen reference
555-233-5061284 Issue 5 October 2002
Outgoing Last Digit (sec)
This field is only administrable if the Trunk Type field is dis or cont and the trunk
group Direction field is
two-way or outgoing. Only TN497 and TN2140 ports
receive this timer.
Outgoing Rotary Dial Interdigit (msec)
This field only appears when:
1. the trunk group Group Type field is
access, aplt, co, diod, dmi-bos, fx,
rlt, tandem, or wats and the Outgoing Dial Type field is rotary
2. the Group Type field is tie, the Trunk Type field is blank, cont, or dis, and
the Outgoing Dial Type field is
rotary
3. the Group Type field is tie, and the Trunk Type field is tge, tgi, or tru (the
Outgoing Dial Type field does not appear but is implied to be
rotary).
Outgoing Seizure (msec)
Appears when the Country field is 15, the Direction field is outgoing or two-way,
and the Trunk Type field is
2-wire-ac, 2-wire-dc, or 3-wire. This timer is sent
only to the TN2199 circuit pack.
Valid entries Usage
1
to 40 in
increments of
1
Enter the maximum time that the switch will wait for the next
digit dialed. After the timer expires, no more digits are
accepted by the circuit pack.
Valid entries Usage
150
to 2550
in increments
of 10
Enter the minimum time between outpulsed digits on
outgoing rotary trunks.
Valid entries Usage
20
to 2550 in
increments of
10
Enter the duration of the outgoing seizure signal.