Marginal Threshold - +Dev - 404 Hz Loss
Marginal Threshold - -Dev - 2804 Hz
Marginal Threshold - +Dev - 2804 Hz
Marginal Threshold - Max - 1004 Hz Loss
Marginal Threshold - Min -1004 Hz Loss
Valid entries Usage
0
to 9 Enter the maximum positive deviation of measured loss at
404 Hz from the 1004 Hz test tone loss level (in dB) allowed
before reporting a trunk as out of tolerance. Smaller dB
values are more restrictive.
Valid entries Usage
0
to 9 Enter the maximum negative deviation of measured loss at
2804 Hz from the 1004 Hz test tone loss level (in dB)
allowed before reporting a trunk as out of tolerance. Smaller
dB values are more restrictive.
Valid entries Usage
0
to 9 Enter the maximum positive deviation of measured loss at
2804 Hz from the 1004 Hz test tone loss level (in dB)
allowed before reporting a trunk as out of tolerance.
Smaller dB values are more restrictive.
Valid entries Usage
0
to 21 Enter the maximum signal loss allowed for a 1004 Hz test
tone (in dB) before a trunk is reported as out of tolerance. A
smaller dB value is more restrictive.
Valid entries Usage
-2
to 21 Enter the minimum signal loss allowed for a 1004 Hz test
tone (in dB) before a trunk is reported as out of tolerance. A
larger dB value is more restrictive.