Facility and Non-Facility Associated Signaling
Issue 5 October 2002 1683555-233-506
Screen 308. Signaling Group screen (Group 3) Facility Associated
Signaling
Note the following details in the Signaling Group screens shown above:
Signaling Group 1 B-channels on DS1 circuit packs (boards) B0 and B1 are
signaled by D-channel pair B1524 (see the Primary D-channel field) and
B1624 (see the Secondary D-channel field).
Signaling Group 2 B-channels on board B1 are signaled by D-channel
B1824.
Board B0 has no D-channel. The B-channels on board B0 can be signaled
by either D-channel pair B1524/B1624 (Signaling Group 1) or D-channel
B1824 (Signaling Group 2).
The DS1 interface on board B19 (Signaling Group 3) is a Facility
Associated Signaling case. Note that the Secondary D-channel and Trunk
Board/Interface ID fields are not displayed when the Associated Signaling
field is
y.
The following 2 communications-interface screens must be completed for the
ISDN-PRI interface on DEFINITY SI configurations if the D-channel is switched
through the TN765 Processor Interface (PI) circuit pack:
Interface Links screen Used to create an association between the
D-channel on a DSI circuit pack and the port on a TN765 Processor
Interface circuit pack used for this link.
Processor Channels screen Used to assign processor channels to the link
administered on the Interface Links screen.
Finally, trunk ports are added to the ISDN-PRI trunk group and to Signaling
Groups.
SIGNALING GROUP
Group Number : 3 Associated Signaling? y Max number of NCA TSC: 0
Primary D-Channel: 1B1924 Max number of CA TSC: 0
Trunk Group for NCA TSC: __
Trunk Group for Channel Selection: _____