Administrator's Guide
Facility and Non-Facility Associated Signaling
Issue 5 October 2002 1683555-233-506
Screen 308. Signaling Group screen (Group 3) — Facility Associated
Signaling
Note the following details in the Signaling Group screens shown above:
■ Signaling Group 1 B-channels on DS1 circuit packs (boards) B0 and B1 are
signaled by D-channel pair B1524 (see the Primary D-channel field) and
B1624 (see the Secondary D-channel field).
■ Signaling Group 2 B-channels on board B1 are signaled by D-channel
B1824.
■ Board B0 has no D-channel. The B-channels on board B0 can be signaled
by either D-channel pair B1524/B1624 (Signaling Group 1) or D-channel
B1824 (Signaling Group 2).
■ The DS1 interface on board B19 (Signaling Group 3) is a Facility
Associated Signaling case. Note that the Secondary D-channel and Trunk
Board/Interface ID fields are not displayed when the Associated Signaling
field is
y.
The following 2 communications-interface screens must be completed for the
ISDN-PRI interface on DEFINITY SI configurations if the D-channel is switched
through the TN765 Processor Interface (PI) circuit pack:
■ Interface Links screen — Used to create an association between the
D-channel on a DSI circuit pack and the port on a TN765 Processor
Interface circuit pack used for this link.
■ Processor Channels screen — Used to assign processor channels to the link
administered on the Interface Links screen.
Finally, trunk ports are added to the ISDN-PRI trunk group and to Signaling
Groups.
SIGNALING GROUP
Group Number : 3 Associated Signaling? y Max number of NCA TSC: 0
Primary D-Channel: 1B1924 Max number of CA TSC: 0
Trunk Group for NCA TSC: __
Trunk Group for Channel Selection: _____