Administrator's Guide

Administered Connection
Issue 5 October 2002 601555-233-506
Start Days (Sun through Sat)
These fields indicate only the days on which an attempt will be made to establish
the AC and not necessarily the days it is active. A scheduled AC may be active
over a number of days, and, in this situation, these fields should be used only to
specify the days on which the AC starts and not other days on which the AC may
be active. Only appears if the Continuous field is
n.
Start Time
Only appears if the Continuous field is n.
Miscellaneous Parameters
Alarm Threshold
Only appears if an entry in the Alarm Type field is other than none. Enter the
number of times an attempt to establish or reestablish an AC must fail
consecutively before an AC alarm generates. (An alarm will be generated after the
fourth retry has failed; thus, with the retry interval of 2 minutes, an alarm will be
generated approximately 8 minutes after the first failure occurs.)
Valid entries Usage
y Enter y in each of the required days of the week fields to
indicate that an attempt will be made to establish the AC.
n Displays the day fields.
Valid entries Usage
00:00
through 23:59 Enter the time of the day when an attempt
should begin to establish a scheduled AC. The
time is specified in two fields separated by a
colon.
Valid entries Usage
1