Administrator's Guide

Screen reference
555-233-506608 Issue 5 October 2002
Port
For External Announcements (analog, Lineside T1/E1, or Aux. Trunk). Enter the
necessary characters in the
aaxssyy format (where aa = the cabinet number, x =
the carrier,
ss = the slot number, and yy = the circuit number).
For example, 01A0612 is in cabinet 01, carrier A, slot 06, and circuit number
(port) 12.
For Integrated Announcements (TN750 or TN2501AP (VAL) circuit pack). Enter
the necessary characters in the
aaxss format (where aa = the cabinet number, x =
the carrier, and
ss = the slot number).
For example, 01A06 is in cabinet 01, carrier A, and slot 06.
Valid entries Usage
01
through 44
(DEFINITY R) or
01 through 03
(DEFINITY CSI, SI) or
1 through 64
(S8700 IP-Connect /
S8700 Multi-Connect)
First and second characters are the cabinet
number.
A through E Third character is the carrier.
0 through 20 Fourth and fifth characters are the slot number.
00 through 32 Six and seventh characters are the circuit
number.
Valid entries Usage
01
through 44
(DEFINITY R) or
01 through 03
(DEFINITY CSI, SI) or
1 through 64
(S8700 IP-Connect /
S8700 Multi-Connect)
First and second characters are the cabinet
number.
A through E Third character is the carrier.
0 through 20 Fourth and fifth characters are the slot number.