Administrator's Guide

Data modules
Issue 5 October 2002 727555-233-506
Screen 87. Data Line Data Module if KYBD Dialing is n
See ‘‘DLC Option Settings’’ on page 732 for additional information when
assigning entries for the remaining fields on the screen.
CAPABILITIES
Busy Out
This option should be enabled for DTEs that are members of a hunt group and to
allow busy out when DTE turns power off so that calls do not terminate on that
DTE.
Configuration
Appears when the KYBD Dialing field is y. This option normally is enabled for
originate/receive DTE such as non-intelligent terminals and disabled for
intelligent devices such as computers. The KYBD Dialing field must be
y with
this option.
KYBD Dialing
This option must be enabled to allow data endpoints to originate calls via the EIA
232C interface and obtain ASCII feedback text. When enabled, the user gets the
dial prompt. This option normally is enabled for originate/receive DTE that has
Valid
entries Usage
y/n
Enter y to place the DLC port in a busied-out state once the
DTE control lead to the DLC is dropped.
Valid
entries Usage
y/n
Enter y to allow the viewing and changing of options from
the DTE.
change data-module 30 DATA MODULE Page 2 of 2
CAPABILITIES
KYBD Dialing? n
Busy Out? n
SPEEDS
Low? y 1200? y 4800? y 19200? y
300? y 2400? y 9600? y
OPTIONS
Permit Mismatch? n