Administrator's Guide

Data modules
Issue 5 October 2002 739555-233-506
BRI LINK/MAINTENANCE PARAMETERS
Country Protocol
Used with World Class BRI Data Modules. Enter the protocol that corresponds to
your supported initialization and codesets. The Country Protocol must match any
previously-administered endpoint on the same port. The following table lists the
valid protocol entries.
Endpt ID
Used with World Class BRI Data Modules. Appears only if the Endpt Init field is
y. This field provides for multipoint configuration conformance to the Bellcore
Terminal Initialization procedures. In these procedures, a multipoint configuration
requires that the last 2 digits of the Service Profile Identifier (SPID) be between
00 and 63 and be binary unique for each endpoint. This field, combined with the
SPID, gives the effective SPID administered into the terminal. Bellcore ISDN-1
requires that the SPID programmed into the endpoint contain at least 9 digits. (For
example, if the SPID field is
1234, and the Endpt ID field is set to 01, then the
SPID administered on the terminal is 000123401. The three leading zeros are
necessary to create a 9-digit SPID.)
Endpt Init
Used with 7500 and World Class BRI Data Modules. Endpoint initialization is a
procedure, required for multipoint operation, by which User Service Order Profile
(USOP) is associated with an endpoint on the ISDN-BRI. This association is
made via the Service Profile Identifier (SPID), administered into the system and
entered into the ISDN-BRI terminal. For a ISDN-BRI terminal to become
operational in a multipoint configuration, both the administered SPID and the
Country/Area Protocol
Australia 2
ETSI (Europe) etsi
Japan 3
Singapore 6
United States (Bellcore National ISDN) 1
Valid entries Usage
00
through 62
Enter a 2-digit number. Each Endpt ID field must have a
unique value for each endpoint on the same port.