Administrator's Guide

Screen reference
555-233-506766 Issue 5 October 2002
Line Compensation
The appropriate entry in this field varies with the type of cable used, so work with
your network service provider to determine the correct setting in your situation.
The following table shows the appropriate entries for different lengths of
22-gauge ABAM cable terminated on a DSX-1 cross-connect.
The following table shows the appropriate entries for different lengths of
22-gauge ABAM cable directly connecting to DS1 interfaces.
Location
This display-only field shows the port address specified in the add command
when the circuit pack was first administered.
MMI Cabling Board
This field appears only if the MMCH field is y on the System-Parameters
Customer-Options screen.
Valid
entries Usage
1
Length: 000133 (ft), 000-40.5 (m)
2
Length: 133266 (ft), 40.581.0 (m)
3
Length: 266399 (ft), 81.0122 (m)
4
Length: 399533 (ft), 122163 (m)
5
Length: 533655 (ft), 163200 (m)
Valid
entries Usage
1
Length: 00000266(ft), 000081(m)
2
Length: 02660532(ft), 081162(m)
3
Length: 05320798(ft), 162243(m)
4
Length: 07981066(ft), 243325(m)
5
Length: 10661310(ft), 325400(m)
Valid entries Usage
slot address
(cabinet,
carrier, slot)
Enter the slot location (cabinet, carrier, slot) of the
multimedia interface circuit pack that is connected to the
Expansion Services Module (ESM).