Administrator's Guide

Feature-Related System Parameters
Issue 5 October 2002 837555-233-506
Field descriptions for page 9
Screen 119. Feature-Related System Parameters screen
Allow Conference via Flash
Charge Display Update Frequency (seconds)
This applies only if you use Advice of Charge or Periodic Pulse Metering with
display functions.
Valid entries Usage
y
Enter y to allow an analog station to use flash to conference
calls together.
n
Enter n to prevent this.
Valid entries Usage
10
60 or
blank
The amount of time (in seconds) between charge-display
updates. Frequent display updates may have considerable
performance impact. If the duration of a call is less than the
Charge Display Update Frequency, the display will not
automatically show charge information. To see charge
information for a call, the user must have a disp-chrg button
and must press the button before the call drops.
change system-parameters features page 9
FEATURE-RELATED SYSTEM PARAMETERS
Pull Transfer: n Update Transferred Ring Pattern? n
Outpulse Without Tone? y Wait Answer Supervision Timer? n
Misoperation Alerting? n Repetitive Call Waiting Tone? y
Allow Conference via Flash? y Repetitive Call Waiting Interval (sec): _
Vector Disconnect Timer (min): __ Network Feedback During Tone Detection? y
Hear Zip Tone Following VOA? y System Updates Time On Station Displays? n
Intercept Treatment On Failed Trunk Transfers? n
Station Tone Forward Disconnect: silence
Level Of Tone Detection: precise
Charge Display Update Frequency (seconds): 30
Date Format on 607/2420/4600/6400 Terminals: mm/dd/yy
On-hook Dialing on 607/2420/4600/6400/8400 Terminals? n
RECALL TIMING
Flashhook Interval? y Upper Bound (msec): 1000
Lower Bound (msec): 200
Forward Disconnect Timer (msec): 600
ITALIAN DCS PROTOCOL
Italian Protocol Enabled? y
Apply Intercept Locally? _ Enforce PNT-to-PNT Restrictions? _