Avaya Installation Guide Avaya P114T STACKABLE WORKGROUP SWITCH
Preface Important information SAFETY PRECAUTIONS CAUTION – TO REDUCE THE RISK OF ELECTRIC SHOCK AND FIRE 1. All servicing should be undertaken ONLY by qualified personnel. The parts inside the unit CANNOT be serviced or repaired by the end user. Please call your service representative for assistance. 2. Do NOT plug in, turn on or attempt to operate a damaged unit. 3. Ensure that the chassis ventilation slots in the unit are NOT BLOCKED. 4.
Preface Safety Instructions 3. 4. 5. 6. 2 Vergewissern Sie sich, dass die Chassis Ventilationsöffnungen des Gerätes NICHT BLOCKIERT sind.6 Austauschen einer durchgebrannten Sicherung NUR mit der gleichen Sorte und Belastbarkeit wie sie auf der Sicherheitsaufschrift markiert ist. Die Aufschrift befindet sich neben der Stromzufuhr wo sich auch der Sicherungskasten befindet. Bedienen Sie das Gerät NICHT an einer Stelle an der die Umgebungstemperatur 50ºC übersteigt.
Chapter 1 Overview This guide is divided into two sections: • Overview: A general description of the features of the Avaya P114T Stackable Switch. • Installation: Instructions for getting the P114T Stackable Switch and P110 Switching System up and running. Description The P114T Stackable Switch is part of the P110 Switching System family of workgroup switches.
Chapter 1 4 Description P114T Stackable Switch Installation Guide
Chapter 2 Installation Setting the DIP switches First, set the DIP switches. The position of the switches depends on the P110 application. The drawing below shows the default positions of the DIP switches on the rear panel of the P110 hub. Figure 1 The P114T Stackable Switch Rear Panel Showing The DIP Switches In their Default Positions The DIP switches control the eight 100 Mbps ports. The ports can also be controlled by CajunView, MSNM, or any SNMP network management application via the P110 NMA.
Chapter 2 Installation Table 1 DIP Switches on the P114T Stackable Switch Switch Function (First three leftmost switches) Not used USE SW Selection of operational (Use Switches) mode: control by management station or DIP switches. Switches 1-8 Selection of port speed ON OFF (Default) Use management Ignore management settings. settings. Ignore switches. Use switches. 10 Mbps 100 Mbps Once you have set the switches, you may proceed with the physical installation of the hub.
Chapter 2 Installation Installing the P114T Stackable Switch The procedure for getting the P114T Stackable Switch up and running depends on whether the hub is to operate standalone or as part of a stack. First, attach the adhesive rubber feet to the base of the P110 switch. If the switch is to be rack mounted, do not attach the feet. Standalone Operation - Plug ‘n’ Play Getting the P110 hub working is quick and easy: 1. Connect the power cable to the hub, 2.
Chapter 2 Installation All ports will lose their VLAN assignment and will be reassigned to Generic VLAN. • The Administration Status of all P110 switches will be Enabled. In order to avoid any possible loops, any port that you disabled using the management software must be physically disconnected before software download. Once you have downloaded the new software, set the port to disabled again and then reconnect the cable. 6. Place the P114T and any other additional P110 hubs at the bottom of the stack.
Chapter 2 6. 7. 8. Installation Two terminators are supplied with the P110 NMA. Insert the two terminators into the lowest two connectors at the bottom of the stack, as shown in Figure 2. Turn on the mains power to the stack, by individually switching on each switch. Connect the fiber-optic cables to the front panel ports. If the P110 NMA in the stack contains the correct software version (as specified in the P114T Stackable Switch Release Note) or higher, the stack is now fully operational.
Chapter 2 Installation Rack Mounting P110 switches slot into a standard 19-inch rack. Remove the rubber legs from the base of any switch that is to be rack mounted. Place the switches in the rack, and then connect the P110 Exoplane, as follows: 1. Snap open the ends of the front panel to reveal the fixing holes. 2. Slot the switch into the rack. Insert the switches into the rack so that the switches in a logical stack lie directly on top of each other.
Chapter 2 Installation Diagnostics Table 2 and Table 3 explain the meaning of the P114T Stackable Switch diagnostic LED indicators. Figure 4 The P114T Stackable Switch Front Panel LEDs and Buttons Table 2 Button Function Select Meaning of the P114T Stackable Switch Front Panel Buttons Meaning The buttons determine what function will be displayed by the 8 Port LEDs (the top row of LEDs). The seven Function LEDs (above the Select buttons) show which function is currently displayed by the Port LEDs.
Chapter 2 Installation Table 3 Meaning of the P114T Stackable Switch front panel LEDs LED Indicator Function Status Meaning PWR Power OFF ON Blink Mains power not connected Mains power connected Working on back-up power supply NMA Agent OFF ON No agent in hub Hub contains an active agent RED NMA Reserved for future use Port LEDs 1 to 8 Each LED can display one of the following functions: Link, Collision, Transmit, Receive, Full Duplex, Flow Control or 100 M states, depending on what has
Chapter 2 P114T Stackable Switch Installation Guide Installation 13
© 2003 Avaya Inc. All rights reserved. All trademarks identified by the ® or TM are registered trademarks or trademarks, respectively, of Avaya Inc. All other trademarks are the property of their respective owners. Document number: 130005 Rev. 0.