Part No.
Copyright © 2000 Nortel Networks All rights reserved. Printed in the USA. January 2000. The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must take full responsibility for their applications of any products specified in this document. Trademarks NORTEL NETWORKS is a trademark of Nortel Networks.
Japan/Nippon Requirements Only Voluntary Control Council for Interference (VCCI) Statement Taiwan Requirements Bureau of Standards, Metrology and Inspection (BSMI) Statement Canada Requirements Only Canadian Department of Communications Radio Interference Regulations This digital apparatus (T1/FT1 Adapter Module) does not exceed the Class A limits for radio-noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications.
Canada Requirements Only (continued) Canada CS-03 Rules and Regulations Notice: The Industry Canada label identifies certified equipment. This certification means that the equipment meets telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document(s). The Department does not guarantee the equipment will operate to the user’s satisfaction.
FCC Part 68 Compliance Statement This equipment complies with Part 68 of FCC Rules. All direct connections to telephone network lines must be made using standard plugs and jacks compliant with FCC Part 68. Please note the following: 1. You are required to request service from the telephone company before you connect the unit to a network.
software or other Nortel Networks software products are licensed for use under the terms of the applicable Nortel Networks NA Inc. Software License Agreement that accompanies such software and upon payment by the end user of the applicable license fees for such software. 2. Restrictions on use; reservation of rights. The Software and user manuals are protected under copyright laws.
agencies, and subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause of DFARS 252.227-7013, for agencies of the Department of Defense or their successors, whichever is applicable. 6. Use of Software in the European Community. This provision applies to all Software acquired for use within the European Community.
Contents Preface Before You Begin ............................................................................................................. xv How to Use This Supplement ..........................................................................................xvi Text Conventions ............................................................................................................xvii Acronyms ........................................................................................................
Chapter 4 Using the T1/FT1 Adapter Module In a Passport 2430 Multiservice Access Switch Attaching Cables ............................................................................................................4-1 Completing Software Configuration ................................................................................4-2 Interpreting LEDs ...........................................................................................................4-3 x 118943-B Rev.
Figures Figure 1-1. T1/FT1 Adapter Module Cable Connection and LEDs .............................1-2 Figure 1-2. AN or 12-Port ANH T1/FT1 Adapter Module ...........................................1-3 Figure 1-3. 8-Port ANH T1/FT1 Adapter Module ........................................................1-3 Figure 1-4. T1/FT1 Adapter Module LEDs .................................................................1-4 Figure 2-1. T1/FT1 Adapter Module Cable Connection ......................................
Tables Table 1-1. PROM Diagnostic and Boot Code for AN/ANH Routers ..........................1-1 Table 1-2. T1/FT1 LEDs ............................................................................................1-5 Table 2-1. PROM Diagnostic and Boot Code for ARN Routers ................................2-1 Table 2-2. T1/FT1 LEDs ............................................................................................2-3 Table 3-1. Example WAN Adapter Module Combinations .......................
Preface The T1/FT1 Adapter Module provides high-speed connectivity to the digital services networks in North America. It is capable of operating at fractional T1 rates, in increments of 64 Kb/s, up to 1.544 Mb/s. Before You Begin This guide is intended for qualified service personnel who are installing the T1/FT1 Adapter Module in an AN/ANH, ARN, Passport 5430, or Passport 2430 for the first time or who need to install or replace any customer-replaceable unit (CRU).
T1/FT1 Adapter Module Supplement How to Use This Supplement This WAN adapter module can be used with several different platforms. Refer to the table below to find the chapter that contains the information appropriate for the platform you are using.
Preface Text Conventions This guide uses the following text conventions: bold text Indicates command names and options and text that you need to enter. Example: Enter the diags command. italic text Indicates new terms, book titles, and variables in command syntax descriptions. Acronyms This guide uses the following acronyms: CRU customer-replaceable unit IP Internet Protocol Hard-Copy Technical Manuals You can print selected technical manuals and release notes free, directly from the Internet.
T1/FT1 Adapter Module Supplement How to Get Help If you purchased a service contract for your Nortel Networks product from a distributor or authorized reseller, contact the technical support staff for that distributor or reseller for assistance.
Chapter 1 Using the T1/FT1 Adapter Module in a BayStack AN or ANH Router This chapter supplements Installing an Adapter Module in a BayStack AN or ANH Router. Follow the hardware installation steps in that manual, then refer to this document for information specific to the T1/FT1 adapter module. Verifying AN/ANH Router Requirements Table 1-1 shows the minimum boot and diagnostic programmable read-only memory (PROM) code required for the T1/FT1 adapter modules. Table 1-1.
T1/FT1 Adapter Module Supplement Attaching Cables Connect the T1 communication device cable to the RJ-48C connector on the installed T1/FT1 adapter module (Figure 1-1). Complies with FCC Rules Part 68 Reg. Number 4P8USA-31445-DE-N T1/FT1 DSU/CSU Red Alm Loop Yel Alm Sync AN0125A Figure 1-1.
Using the T1/FT1 Adapter Module in a BayStack AN or ANH Router UL UL XCVR UTP CO M 2 CONSOLE TX RX CL COM 1 100-240V 50-60 Hz 1.0-0.5A RST RLSD2 RLSD1 AN0123A Complies with FCC Rules Part 68 Reg. Number 4P8USA-31445-DE-N FT1/T1 DSU/CSU Figure 1-2. Red Alm Loop Yel Alm Sync AN or 12-Port ANH T1/FT1 Adapter Module COM 2 COM 1 COM 3/Expansion Red Alm Loop Yel Alm Sync FT1/T1 Complies with FCC Rules Part 68 DSU/CSU Reg. Number 4P8USA-31445-DE-N AN0124A Figure 1-3.
T1/FT1 Adapter Module Supplement Completing Software Configuration Once you have successfully installed the adapter module, complete the following software configuration tasks using instructions found in your BayRS documentation: Configuration Task Location of Instructions Connect the AN/ANH to the network.
Using the T1/FT1 Adapter Module in a BayStack AN or ANH Router Table 1-2 describes the function of each T1/FT1 LED. Table 1-2. 118943-B Rev 00 T1/FT1 LEDs Label Color Meaning Red Alm Red Lights when the T1 port is in a red alarm state. Yel Alm Amber Lights when the DSU/CSU has received a yellow alarm from the T1 network. Loop Amber Lights when the T1 interface is placed in loopback mode. Sync Green Lights when the T1 port is synchronized with the T1 network.
Chapter 2 Using the T1/FT1 Adapter Module in a BayStack ARN Router This chapter supplements Installing and Operating BayStack ARN Routers (Chapter 4, “Installing a WAN Adapter Module”). Follow the hardware installation steps in that manual, then refer to this document for information specific to the T1/FT1 adapter module. Verifying ARN Router Requirements Table 2-1 shows the minimum boot and diagnostic programmable read-only memory (PROM) code required for the T1/FT1 adapter modules. Table 2-1.
T1/FT1 Adapter Module Supplement ARN front panel 1 Complies with FCC Rules Part 68 Reg. Number 4P8USA-31445-DE-N T1/FT1 DSU/CSU 2 To T1 device ARN0090A Figure 2-1. T1/FT1 Adapter Module Cable Connection You install the T1/FT1 adapter module in one of the two front-panel WAN adapter module slots (Figure 2-1). See Installing and Operating BayStack ARN Routers.
Using the T1/FT1 Adapter Module in a BayStack ARN Router For the latest information, be sure to review the release notes and documentation change notice for your version of BayRS software. Interpreting LEDs The T1/FT1 adapter module LEDs (Figure 2-2) will blink on and off during diagnostic testing, but they will not stay on to indicate data transfer until you have configured and enabled T1/FT1 software services. T1/FT1 DSU/CSU Red Alm Loop Yel Alm Sync ARN0106A Figure 2-2.
Chapter 3 Using the T1/FT1 Adapter Module in the Passport 5430 Multiservice Access Switch This chapter supplements Installing and Operating the Passport 5430 Multiservice Access Switch. Follow the hardware installation steps in that manual, then refer to this document for information specific to the T1/FT1 adapter module.
T1/FT1 Adapter Module Supplement In the example above, the first ISDN BRI module (in Module slot 3) has the resources to bring up a second B channel (thus using 2 circuits). The serial adapter in Module slot 4 uses a third circuit. The second ISDN BRI adapter module (in Module slot 5), can have only 1 B channel configured because the serial adapter module (in Module slot 4) has priority and is allocated a circuit over anything in Module slot 5.
Using the T1/FT1 Adapter Module in the Passport 5430 Multiservice Access Switch Table 3-1. Example WAN Adapter Module Combinations Module 3 Module 4 Module 5 T1/FT1 or E1/FE1 T1/FT1 or E1/FE1 T1/FT1 or E1/FE1 T1/FT1 or E1/FE1 T1/FT1 or E1/FE1 Serial or V.34 modem T1/FT1 or E1/FE1 Serial or V.34 modem Serial or V.34 modem T1/FT1 or E1/FE1 T1/FT1 or E1/FE1 ISDN 2 B-channels plus 1 D-channel T1/FT1 or E1/FE1 ISDN BRI 1 B-channel plus 1 D-channel Serial or V.
T1/FT1 Adapter Module Supplement Attaching Cables Connect the T1 communication device cable to the RJ-48C connector on the installed T1/FT1 adapter module (Figure 3-1). Module 3 U ISDN BRI with NT1 COM Module 4 Complies with FCC Rules Part 68 Reg. Number 4P8USA-31445-DE-N Module 5 T1/FT1 DSU/CSU Telco Remote Console V.34 Modem To T1 device FBR0020A Figure 3-1. T1/FT1 Adapter Module Cable Connection You install the T1/FT1 adapter module in one of the three front-panel Module slots (Figure 3-1).
Using the T1/FT1 Adapter Module in the Passport 5430 Multiservice Access Switch Completing Software Configuration Once you have successfully installed the adapter module, complete the following software configuration tasks using instructions found in your BayRS documentation: Configuration Task Location of Instructions Modify the configuration file to add the One of the following: T1/FT1 module and enable default software • Configuring and Managing Routers with services.
T1/FT1 Adapter Module Supplement Table 3-2 describes the function of each T1/FT1 LED. Table 3-2. 3-6 T1/FT1 LEDs Label Color Meaning Red Alm Red Lights when the T1 port is in a red alarm state. Yel Alm Amber Lights when the DSU/CSU has received a yellow alarm from the T1 network. Loop Amber Lights when the T1 interface is placed in loopback mode. Sync Green Lights when the T1 port is synchronized with the T1 network.
Chapter 4 Using the T1/FT1 Adapter Module In a Passport 2430 Multiservice Access Switch This chapter supplements Installing and Operating the Passport 2430 Multiservice Access Switch. Follow the hardware installation steps in that manual, then refer to this document for information specific to the T1/FT1 adapter module. Attaching Cables Connect the T1 communication device cable to the RJ-48C connector on the installed T1/FT1 adapter module (Figure 4-1).
T1/FT1 Adapter Module Supplement You install the T1/FT1 adapter module in one of the two rear-panel slots on the Passport 2430 (Figure 4-1). See Installing and Operating the Passport 2430 Multiservice Access Switch. Completing Software Configuration Once you have successfully installed the adapter module, complete the following software configuration tasks using instructions found in your BayRS documentation: Configuration Task Location of Instructions Connect the Passport 2430 to the network.
Using the T1/FT1 Adapter Module In a Passport 2430 Multiservice Access Switch Interpreting LEDs The T1/FT1 adapter module LEDs (Figure 4-2) will blink on and off during diagnostic testing, but they will not stay on to indicate data transfer until you have configured and enabled T1/FT1 software services. T1/FT1 DSU/CSU Red Alm Loop Yel Alm Sync ARN0106A Figure 4-2. Passport 2430 T1/FT1 Adapter Module LEDs Table 4-1 describes the function of each T1/FT1 LED. Table 4-1.